Military Engineer Services - Madhya Pradesh
40665968 tender for repair / maintenance of ceilling fans, exhaust fan and connected works at af station gwalior; taking down carefully condensor, down rod, canopy , fan blade, nut, bolts and washers, rubber real, condensor cap, exhaust fan clamp, exhaust fan frame with existing surface all as specified and directed by engineer in charge. note: ( a ) adequate nos electricians & helpers shall be present at office of age e / m ( af ) aa maharajpur, engineer ln charge at 9am every day for taking forinstructions regarding repair work to be carried out on the day on priority.t&p required inclusive safety equipment & transport required to carry out regular repair electrician, work in domestic area or any area of airforce station gwalior. ( b ) alternative electrician shall be deployed in place of regular electrician to attend work on sunday / holiday area of air force station faults / defects / complaints, if alternative electrician fails to report or found absent or fails to rectify the faults then recovery shall be recovered from contractors any due payment ( c ) the repair work on any single day may beordered by engineer in charge to be carry out in number of places / building in one day i.e in one buildings quantity of any of boq items to be carried may be one or more number of boq items to be executed on any single day may also be one or more ( d ) contractor shall not have any claim on account of order of one or more quantity of one or more items of boq that to be executed in one or more buildingand or area in any single day & even the same on any numbers of day during contract period & all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for allitems of boq of this tender. 2 disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans etc. of any description, any sweep and from any position / locations ( i.e. md accn / otm accn ) for repairs / servicing / overhauling / painting / numbering etc dismantlinf and opening of the checking serviceablity of parts, overhauling, hanging / fixing the fans in position after repairs i.e overhauling by necessary cleaning, oiling & greasing , removing & replacement of defective / unserviceable parts, with new parts, reassembling the fans, making necessaryadjustment , proper alignment of blades, connecting to existing electric sources and testing at site to the entire satisfaction of engineer in charge complete all as specified and directed.note: ( i ) the replacement of defective / nonfunctional parts shall be measured & paid for separately as “supply only” under appropriate item of sch ‘a’ / boq and fixing charges for new items are deemed to be included under this item. ( ii ) burnt out windings replaced, shall be measured and paid for separately under appropriate item of sch ‘a’ / boq for rewinding. ( iii ) the rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the engineer in charge for necessary repairs. ( iv ) writing of fan no. and painting of fans shall be measured and paid for separatelyunder appropriate item of sch ‘a’ / boq 3 taking out & removing old burnt out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire ( make : atlas / finolex / devi dayal ) as approved by the engineer in charge including insulating material such as illuminous paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of engineer in chargefor the following fans: 4 ( a ) rewinding of motor of ceiling fans 1200 / 1400 mm sweep. 5 ( b ) rewinding of motor of exhaust fans of 225 / 230 mm sweep. 6 ( c ) rewinding of motor of exhaust fans of 300 / 375 mm sweep. 7 ( d ) rewinding of motor of exhaust fans of 450 mm sweep. 8 supply only the following new parts suitable for the ceiling / exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep : 9 ( a ) supplying only ball bearing no 6200 10 ( b ) supplying only ball bearing no 6201 11 ( c ) supplying only ball bearing no 6202 12 ( d ) supplying only ball bearing no 6203 13 ( e ) supply only gun metal bushes of any descriptionand size to suit existing motor shaft including grinding & polishing of fan motor shaft to required shape / size. 14 ( f ) supplying only capacitor of capacity 2.5 mfd ( pvc body ) make: epcos / jyoti / usha 15 ( g ) supplying only capacitor of capacity 3.15 mfd ( pvc body ) make: epcos / jyoti / usha 16 ( h ) supplying only capacitor of capacity 4 mfd ( pvc body ) make: epcos / jyoti / usha 17 ( i ) supplying only complete hanging assembly set comprising with rubber reel, ms clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods. 18 ( j ) supply only pvc canopy of any description and suitable for any type & any makeof fan. 19 ( k ) supplying only pvc fan blade assembly with necessary ms nuts, bolts & washers suitable for exhaust fans of any descriptions & of 230 mm sweep.note: set of three blades shall be measured as one unit and make of assembly shall be as approved by ge. 20 ( l ) supplying only aluminium cast metal fan blade assembly with necessary ms nuts, bolts & washers suitable for exhaust fans of any descriptions & of 300 mm sweep. note: set of three blades shall be measured as one unit and make of assembly shall be as approved by ge. 21 ( m ) supplying only aluminium cast metal fan blade assembly with necessary ms nuts, bolts & washers suitable for exhaust fans of any descriptions & of 450 mm sweep.note: set of three blades shall be measured as one unit and make of assembly shall be as approved by ge. 22 ( n ) supply only pvc insulated and sheathed, round flexible cable, three core of size 23 / 0.0076 with copper conductor in pieces for connecting fans. 23 ( o ) supply only ms nuts & bolts with one hole washer & lock pin of suitable size for hanging assembly complete. 24 ( p ) supply only rubber real of suitable size of hanging assemblycomplete. 25 ( q ) supply only condensor cap pvc body 26 ( r ) supply only 300mm long down rod 20mm dia, ms tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc 27 ( s ) supply only 600mm long down rod 20mm dia, ms tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc 28 ( t ) supply only 1200mm long down rod 20mm dia, ms tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc 29 ( u ) supply only 1800mm long down rod 20mm dia, ms tube, light grade, duly finished with powder coating of white colour, including necessary holes and threading etc 30 supply only mild steel fan blade of size 1200 to 1400 mm and of standard thickness ( factory made ) duly balanced and painted of required colour at site 31 supply only exhaust fan clamp ( leg ) for 225 / 300mm exhaust fan as per sample ( set of 3 / 4 ) including rubber packing and clampbolt complete all as specified and directed 32 supply only exhaust fan clamp ( leg ) for 450 mm exhaust fan as per sample ( set of 3 / 4 ) including rubber packing and clampbolt complete all as specified and directed 33 supply only exhaust fan frame for 225 / 300mm exhaust fan as per sample complete all as specified and directed 34 supply only exhaust fan frame for 450 mm exhaust fan as per sample complete all as specified and directed 35 supply only exhaust fan motor for 225 / 250mm exhaust fan as per sample complete all as specified and directed 36 supply only exhaust fan motor for 300 mm exhaust fan as per sample complete all as specified and directed 37 m&l for taking down carefully serviceable ceiling fan / exhaust fan / cabin fan ( any make any size ) from any building and opening the same cleaning each part, oiling and greasing including replacement of worn out parts i.e nut, bolt, screw, split pin, rubber realand re fixing in the same position after repair complete all as specified and directed. 38 disconnecting & removing unserviceable capacitor from existing ceiling fan, exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep fixed in position at any locations ( i.e. md accn / otm accn / hangers ) for replacement with new capacitor of following capacity and testing at site to the entire satisfaction of engineer in charge complete all as specified and directed.: 39 ( a ) capacitor of capacity 2.5 mfd ( pvc body ) ( make:epcos / jyoti / usha ) 40 ( b ) capacitor of capacity 4 mfd ( pvc body ) ( make: epcos / jyoti / usha ) 41 taking down existing worn out louversof any description , in any position and supplying & fixing new louvers made out of ms sheet 22 gaugethick suitable for exhaust fan of 230 / 300mm sweepall as specified & directed by engineer in charge.note: the louvers shall be of shape, size and pattern as approved by the engineer in charge duly painted with two of synthetic enamel paint over a coat of red oxide primer 42 all as per item no.7.00as here in before but suitable for exhaust fan of450 mm sweep 43 disconnecting & taking out old existing unserviceable fan regulator of any description & in any position / location. 44 supplying, fixing, connecting & testing of fan regulator ( electronic step type ) all as specified & directed by engineer in charge make: anchor / crompton / usha / bajaj 45 supplying, fixing fan hook made of of flat iron of suitable size and length, fixed with and including nut, bolts of suitable size including drilling holes for grouting nut, bolt etc complete all as specified & directed. 46 s&f ms clamps for fixing of fan hook as per sample made out of 5 mm thick ms flat including necessary cutting, drilling, welding and provision of necessary nut and bolts etc complete all as specified and directed. 47 m&l for repair to ceiling fan / exhaust fan / wall mounted fan shaft by means of remetalling, grinding & polishing to make with the original size and shape and suitable for fixing of bearing of bush and repairing of bearing housing as required complete all as specified and directed. 48 m & l for painting of existing fans of any description ( ceiling fan / exhaust fan / air circulators / wall mounted fans / pedestal fan ) with applying one coat of synthetic enamel paint ( white ) by spray machine including preparation of existing decorated surfaces of fans including engraving mes no. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed. 49 s&f in replacement of armature with shaft for ceiling fas 1200 / 1400 mm sweep as per sample. 50 s&f in replacement of top & bottom cover of armature suitable for ceiling fas 1200 / 1400 mm sweep as per sample. 51 supply and fixing exhaust fan, steel body, ac, single phase 230 v of size 230mm sweep with blade, frame and louvers complete all as specifed and directed. 52 supply and fixing exhaust fan, steel body, ac, single phase 230 v of 450mm sweep heavy duty with blade, frame and louvers complete all as specifed and directed. 53 s&f in repair of exhaust fan made of sturdy engineering plastic complete louvers shutter, 230v, 50hz, 1200rpm copper winding of sweep 300mm complete all as specified and directed. 54 s&f in repair of exhaust fan made of sturdy engineering plastic complete louvers shutter, 230v, 50hz, 900rpm copper winding of sweep 225 / 250mm complete all as specified and directed. 55 s&f ceiling fan complete with blades, down rod, electronic regulator and accessories, 230v, 1200mm sweep size, minimum air delivery 210 cfm with seviceable value 6.00 bee, five star rated bldc ( brushless direct current motor ) complelet all as specified and directed. 56 s&f in repair mcb single pole 6 to 32 amps, b series, 10ka, 240 volts complete all as specified 57 s&f in repair mcb single pole and neutral 40 to 63 amps, c series, 10ka, 240 volts complete all as specified 58 s&f in repair mcb tpn / fp 40 to 100 amps, b series, 10ka, 240 volts complete all as specified...