Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh
39794122 tender for additional 1x3.15 mva at narwar s / s under onm dn.ii shivpuri ( nit 29; 1 33 / 11 kv 3.15 mva power transformer old 2 crane charge for loading & unloding of and installation of 33 / 11 kv 3.15 mva power transformer old 3 labour charge for pit digging of power transformer size ( 3.1m x 3.1m x 1.5m ) 14.415 cu.mtr ) 4 33 kv vcb, outdoor porcelain clad type with complete structure and accessories excluding ct & amp pannel 5 plinth digging for vcb of 33kv vcb ( 3x2x0.6 ) 3.6 cu.mtr. 6 labour charge forhandling & installation of 33 kv vcb, outdoor porcelain clad type with complete structure and accessories excluding ct & amp pannel 7 33 kv cts.out door oil immersed type 3 core 200 100 / 5 5 1 amp class 0.5 for differential protection 8 labour charge for installation of 33 kv cts.out door oil immersed type 3 core 200 100 / 5 5 1 amp class 0.5 for differential protection 9 33 kv control & relay panel with static relay for transformer protection 10 labour charge for installation of33 kv control & relay panel with static relay for transformer protection including stand of suitable size 11 11 kv vcb, outdoor porcelain clad type with complete structureaccesssories excluding ct & amp pannel 12 plinth digging for vcb of 11 kv vcb ( 3x2x0.6 ) 3.6 cu.mtr. 13 labour charge for installation of 11 kv vcb, outdoor porcelain clad type with complete structureaccesssories excluding ct & amp pannel 14 11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 15 labour charge for handaling & installation of11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps with earthing arrengment 16 11 kv control & relay panel with static relay for transformer protection 17 labour charge for installation of 11 kv control & relay panel with static relay for transformer protectionincluding stand of suitable size 18 33 kv, isolator 600 amp ( turn and twist type ) 19 labour charge for installation of33 kv, isolator 600 amp ( turn and twist type ) 20 11 kv, isolator 800 amp ( turn and twist type ) 21 labour charge for installation of 11 kv, isolator 800 amp ( turn and twist type ) 22 acsr panther conductor 0.20 sq. inch ( 200 sq.mm al.eq. ) 23 stringing of each 33 kv bus upper and lower including drop jumpering jointing with clamp incoming dp / me to bus 24 stringing of each 11 kv bus upper and lower bus including drop jumpering & jointing with clamp through outgoing vcb / me / dp / upto station transformer 25 stringing of all 33 kv & amp 11 kv jumpers from 33 kvvcb to ptr to 11 kv gantry through11 kv vcb 26 h beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 27 labour charge for pit digging & erection ofh beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 28 h beams 152 x 152 mm., 37.1 kg. / meter 9 meter. long 29 labour charge for pit digging & erection ofh beams 152 x 152 mm., 37.1 kg. / meter 9 meter. long 30 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 31 labour charge forcopper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 32 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 33 labour charge forcopper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 34 copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 35 labour charge forcopper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 36 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 37 labour charge forcopper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 38 d.c. cross arms 8 centre to center ( 100x50x6 mm ) channel 39 labour charge for fixing ofd.c. cross arms 8 centre to center ( 100x50x6 mm ) channel along with 6 no h / w , 6 no disc insulator & fixing of supporting clamp on both the clamp 40 d.c. cross arms 4.8 centre to center ( 100x50x6 mm ) channel 41 labour charge for fixing ofd.c. cross arms 4.8 centre to center ( 100x50x6 mm ) channel 42 horizontal and cross bracing 8 center ( 50x50x6mm ) 43 labour charge for fixing of horizontal and cross bracing 8 center ( 50x50x6mm ) 44 33 kv polymer lightening arrestor gapless type, station type 45 labour charge for fixing 33 kv polymer lightening arrestor gapless type with earthing, 46 9 kv gapless type metal oxide ( 10 ka ) polymer for 33 / 11 kv s / stype 47 labour charge for installation 9 kv gapless type metal oxide ( 10 ka ) polymer for 33 / 11 kv s / stype 48 33 kv single phase pts. 49 labour charge for installation of 33 kv single phase pts. 50 11 kv single phase pts. ( resin molded ) 51 labour charge for installation of 11 kv single phase pts. ( resin molded ) 52 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meterclass of accuracy 0.5 sdlms compliant category a meters along with gsm ( gprs compatible ) modems ( for substation metering ) 53 labour charge for installation of 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meterclass of accuracy 0.5 sdlms compliant category a meters along with gsm ( gprs compatible ) modems ( for substation metering ) 54 bi metallic clamp for power transformer of brass flat 50x50x10 mm 55 labour charge for bi metallic clamp for power transformer of brass flat 50x50x10 mm 56 33 kv, pin insulator polymer composite ( 10kn ) 57 labour charge for for fixing of 33 kv, pin insulator polymer composite ( 10kn ) 58 33 kv top clamps 75x75x6 mm angle 59 fixing of 33 kv top clamps 75x75x6 mm angle 60 11 kv polymer pin insulator 61 labour charge forfor fixing of 11 kv polymer pin insulator 62 11 kv top clamp 65x65x6 mm. angle type 63 fixing of 11 kv top clamp 65x65x6 mm. angle type 64 11 kv ( 45kn ) composite polymer disc insulators 65 labour charge for fixing of 11 kv ( 45kn ) composite polymer disc insulators 66 11 kv strain hardware ( t&c type ) fittings 67 labour charge for fixing of 11 kv strain hardware ( t&c type ) fittings 68 33 kv ( 45kn ) composite polymer disc insulators 69 labour charge for fixing of 33 kv ( 45kn ) composite polymer disc insulators 70 33 kv strain hardware ( t&c type ) fittings suitable for panther 71 sheet metal meter box suitable for h.t. static travector meters with ttb 72 marshelling box with 10 no. connectors 73 labour charge formarshelling box with 10 no. connectors 74 t clamp for 33kv & 11kv bus, substation upto dog 75 labour charge forfor fixing of t clamp for 33kv & 11kv bus, substationupto dog 76 clamps 65x8mm flat ( in numbers ) of ms flat for h.beam ( each weight 3.2 kg ) 77 ms strain plate 65x8mm 250mm long 78 stone block / pre cast block for base pedding ( 450x450x75mm ) 79 concreting of structures & ampfoundation ( 1:3:6 ) 80 labour charge forconcreting of structures & ampfoundation ( 1:3:6 ) 81 h.beam back clamps 65x8mm flat ( in numbers ) 82 stay set complete without stay wire 16 mm. ( painted ) 83 labour charge for stay set complete without stay wire 16 mm. ( painted ) 84 stay wire 7 / 3.15 mm ( 7 / 10swg ) 85 concreting of stay ( 20mm / 25mm ) @ 0.3 cmt per stay 86 labour charge for concreting of stay ( 20mm / 25mm ) @ 0.3 cmt per stay 87 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr. lead of 4.0 mm g.i wire 88 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 89 labour charge forconcreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 90 ptr foundation concreting 1:1:5:3 rio 5.634, 1:5:8 rio 7.545 cmt & ms flat / road 324.87cmt& m.s flate / road 324.87 kg 91 labour charge for erection of ptr foundation concreting 1:1:5:3 rio 5.634, 1:5:8 rio 7.545 cmt & ms flat / road 324.87cmt& m.s flate / road 324.87 kg 92 m.s.nuts and bolts 93 red oxide paint 94 labour charge forred oxide paint 95 aluminium paint 96 labour charge foraluminium paint 97 danger boards enamelled 33 kv 98 fixing ofdanger boards enamelled 33 kv 99 galvanized iron ( gi ) flat 50x6 mm 100 gi pipe 40 mm., ( 3 mtr. each pipe ) ( total no. of pits 3 & set of 4 no. pipe in 2 pits ( 2x1.5x3m=9 cubic mtr ) for neutral and la 101 labour charge of pit digging for g.i. pipe & digging of 0.5 m deep trench for laying of gf flat for complete mesh earthing including back filling 102 earthing rod 3 mtrs. ( gelvanised ) 25 mm rod ( single spike / earth rod 10 pitsdistributed for mesh formation avoiding ptr movement area ) 103 labour charge of bore for chem electrods, tithing , welding 104 gi pipe 150 mm., b class with the length of average depth 32mtr. x 4 no. ( 1 forptr neutral, 1 for 11 kv side mesh, 1 for 33 kv side mesh, 1 for la ) 105 labour charge for bore in murrum / black cotton through driling machine 32.5 mtr deep suitable for 150 mm pip ( 4 pits ) 106 back filling of pit with block cotton soil 107 bentonite compound powder 108 back filling of poles with boulders 109 sgst @ 9% 110 cgst @ 9%...