Bharat Sanchar Nigam Limited - Madhya Pradesh

40534002 tender for comprehensive maintenance, upkeep and operation of electro mechanical services of te building and staff quarters at shivpuri under ba gwalior.; 2 comprehensive maintenance of following electromechnical services as per the asset details, specification and conditions attached and providing one semi skilled labour for upkeep, repair and operation in general shift only. ( a ) e.i. & fans. ( b ) compound lighting ( c ) pumps ( d ) sub station ( e ) e. a. sets ( f ) a.c. system ( g ) fire detection system ( h ) electrical appliances. 3 a ) labour component for upkeep, repair and operation of ems ( one semi skilled labour in general shift per month ) 4 b ) comprehensive maintenance of ems 5 sh ii: preventive maintenance and consumable items as and when required on measurable basis 6 servicing & routine maintenance ( b check ) of followingcapacity of dg set complete with cleaning of air cleaner element, replacement of engine lube oil of proper grade ( seal pack of reputed make ) , replacement of lube oil filter elements, replacement of fuel filter elements, retighten cylinder head nuts, adjust engine valve clearance, replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i / c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of dg set after servicing etc as directed. 7 i ) 125 kva dg sets 8 supply , installation, testing and commissioning of 12 volt, heavy duty , hybrid alloy plate, semi maintenance free , storage type, ready to usebattery set for existingdeasetincludingproper initial factory charging of unit, providing and fixing, terminal and thimbles ( if required ) , greasing the battery terminalscomplete as required.180 ah, 12 volt ( m / s exide fxpo xp180 or equivalent of approved make ) note 1 ) agency shall consider rebate for old battery while quoting of rates. additional requirement to be borned by agency without extra cost. 9 dehydration / filtration of oil of transformer, ht panel and potential transformer along with break down voltage testing before and after filtration, acidity testing after filtration, silica gel change complete as required.note1 ) breakdown voltage of oil after dehydration / filtration shall be minimum 60 kv rms.2 ) total acidity max after dehydration / filtration shall be 0.05 mg koh / gm.3 ) max water content after dehydration / filtration shall be 15 ppm. 10 sh iii: one time maintenance of ems asrequired on measurable basis as per instruction of engineer in charge ( for removal of initial defects in services ) 11 replacement of the following faulty / burnt electrical items / accessories in the existing substation and distribution system, suitable for operation on 3 phase, 33kv / 415v / 230v, 50hz, ac supply system including cleaning of installation and lt panels and distribution boards etc complete with interconnections, testing and commissioningas reqd at site. 12 630 amps. hrc fuse. 13 transformer oil. 14 acsr conductor jumper up to 3.0 mtrs. length. 15 gang operated air break switch in the existing 200 kva , 33 kv outdoor substation complete. 16 threephase lcd multifunction meter indicating v, a, f, pf, power, energy ( m / s l&tnova series, cat. no. wm30kfc3c00 or equivalent similar superior make with c.ts 17 led type indication lampswith suitable rating hrc fuses with base & carrier ( led ofm / s esbee l&t, elr&y240a 240v + elb240a 240v ac or equivalent similar superior make ) 18 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 19 100 amp rating, four pole, mccb with variable thermal magnetic release, ( release range 25 32, 50 63, 80 100a ) breaking capacity 25ka at 415v, 50hz, ac supply and conforms to is / iec 60947 2 ( make and model , m / s l&t dn0 100c or equivalent similar superior make ) with ( ics = 100% icu ) 20 repairing of the existing old and damaged foundation i / c white washing etc. complete as required. 21 painting of the existing ht poles ( 06 nos. ) i / c its cross arms / members etc. complete as required. 22 earthing with g. i. earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required. ( for neutral earthing of the existing transformer ) . 23 providing and fixing 25mmx5mm g. i. strip in 40 mm dia g. i. pipe from earth electrode i / c connection with g. i. nut, bolt, spring washer, excavation and re filling etc. as required. 24 providing and fixing 25mmx5mm g. i. strip on surface or in recess for connections etc. as required. 25 replacement of the following faulty / burnt / damaged electrical items / accessories suitable for operation on 230v / 415v, 50hz, single / three phase ac supply , in the existing electrical installation , fan and fittingsi / c supplying making interconnections, testing & commissioning etc. complete as required: 26 electronic choke for 36 / 40 watt fluorescent lamp . 27 30 watt led lamp with holder ( for campus light ) . 28 1200 mm ( nominal ) size, 40 watt fluorescent tube rod. 29 2.5 mfd condenser ( for ceiling fans ) . 30 9 watt led bulb with holder. 31 20 watt led lamp with holder ( for campus light ) . 32 1200 mm ( nominal ) size, 20 watt led tube rod 33 6 32 amps. single pole c curve mcb. 34 32 amps. triple pole and neutral mcb. 35 starter for 4feet, 40 watt fluorescent fitting. 36 5 / 6 amps piano type switch 37 15 / 16 amp piano type switch 38 3 pin 5 / 6 amp socket outlet 39 6 pin 15 / 16 amp socket outlet 40 supplying and fixing two module stepped type electronic fan regulator. 41 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required 42 1 x 1.5 sq. mm 43 2 x 4 sq. mm 44 supplying and laying 2x4 sqmm. al. pvc insulated and pvc sheathedunarmoured cable in the existing surface / recessed steel / pvc conduit as required 45 repairing / rewinding of the following faulty electrical items / accessories complete with connections, testing and commissioning etc. as reqd: 46 rewinding of 1200 / 1400 mm. sweep ceiling fan. 47 rewinding of 450 mm. sweep exhaust fan. 48 supply, installation, testing and commissioning of following rating and types of prewired fitting complete with all accessories driver and lamps etc., suitable for operation on 230 volts, 50 hz single phase ac supply i / c fixing the same directly on wall / celling including connection with 3x 1.5 sqmm frls pvc insulated copper conductor flexible cable etc as required. ( m / s. bajaj / havells / philips ) . 49 1200 mm ( nominal ) , 20 watts ( + / 2 watts ) energy efficient linear box led batten light having 6500k colour temp., minimum 1900 lumens, 95 lumen / watt efficacy and 0.9 power factor . 50 replacement of the old, life expired fittings with the following rating and type fitting suitable for operation on 230volts, 50 hz, single phase, ac supplyi / c installation the same on the existing bracket on the wall / pole, making interconnections, testing, commissioning etc as reqd at site . ( preferred makes syska / wipro / havells / crompton / bajaj / osram or similar superior make ) . 51 led street light luminaire of nominal wattage 30w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 52 led street light luminaire of nominal wattage 60w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 53 providing and fixing of 300 mm sweep, 1400 rpm domestic exhaust fan suitable for operation on 1 phase, 50 hertz, 220 230 volt ac supplyin existing opening as reqd. ( crompton, bajaj, havells, almonard or s.s.make ) 54 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cm / m / w ) minimum 6.00, air delivery minimum 210 cum / min , 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 55 sh iii: pumps & lt panels 56 sitc of dol motor starter with overload protection and single phase preventor , suitable for operation upto 7.5 hp, 415 volts, 50hz, three phase, monoblock pump set having suitable rating contactor, relay, voltmeter, ampere meter, on / off push button assembly, indicators, connection plate, etc. complete as required. ( m / s. l&t mu c6 dol starter, bch or similar superior make ) . 57 supplying and fixing of 3ph led ammeter accuracy class 1.0 and suitable rating cts complete as required 58 supplying and fixing of 3ph led ammeter accuracy class 1.0. complete as required. 59 sh iv: sac & pac units 60 servicing of existing one no 7 tr capacity high precision air conditioner unit with necessary dismantling of covers wherever required, pressurized wet servicing of evaporator and condenser coil, cleaning of oil stains if any, cleaning of evaporator filters with water , checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring for satisfactory operation of package ac unit, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 61 supplying and top up charging of fresh refrigerant r 22 / m 22 / c 407in the existing window ac / split ac / package ac units unitcomplete as per manufacturer / departmental specifications, etc as required at site.in the pac no.1 & sac 62 carrying out wet servicing of existing one nowindow / split type ac units upto 2.0tr capacitycomplete with completecleaning and washing of indoor and outdoor units , cleaning of filter, checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring , providing necessary tape and thimbles, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 63 supplying and fixing / replacement of following electricalitems, suitable for operation on 230v / 415 v , single phase / three phase , 50hz , ac supply in the existing faulty window ac / split ac units / package ac unitcomplete with installation, making interconnections, testing and commissioning etc.as required at site. ( 1.5 tr window, 1.5 / 2 tr split ac and 3 tr hshf ) ( note: the faulty material / compressorshall be handed over to the agency . the agency shall consider suitable buyback pricewhile quoting for the item ) a ) supplying and fixing ofrunning capacitor 50 mfd 64 repairing of the following faulty components ofexisting split / window type ac units including dismantling , repairing , replacement , reinstallation and labour charges complete in all respect for the same, making interconnection, testing and commissioning etc as reqd at site. 65 rewinding of condenser fan motor of 1.5 / 2 tr split ac 66 sh v: fire detection system & fire extinguishers 67 repairing offollowing zone , existing fire detection control panel i / c cleaning , repairing of zonal cards, mother board, control card, charging system, replacement of the faulty / burnt diodes, integrated circuits, leds and power supply unit etc. complete with testing as required. 68 10 zones main control panel. 69 4 zones local control panel. 70 6 zones local control panel. 71 supplying, installation, testing & commissioning of following type fire detectors and other accessories in the existing fire detection and alarm system completewith all connections etc. as required. 72 smoke detector with built in led and mounting base complete. 73 dual chamber heat detector ( heat cum rate of rise in temperature type ) . 74 responseindicator on surface / recess ms box having two leds and metallic cover complete.. 75 manual call point ( pill box ) of ms construction with stainless steel chain and hammer assembly. 76 fire alarm sounder with facility to make announcement mounted in ms box ( 16 swg ) with hinged cover plate. 77 cleaning of the entire existing detectors installed in the bldg. i / c testing etc. complete as required. 78 refilling / recharging of the following type / capacity fire extinguishers as per bis 2190:2010 specifications including repair of fire extinguishers and replacement of defective spare parts like nozzle, safety clip, horn, water, rings, washer, plunger etc. as required and collection, transportation and delivery charges from various exchanges to refilling station and vice versa etc. complete as required: 79 4.5 kg. portable co2 type fire extinguisher....

Airports Authority Of India - Madhya Pradesh

40470848 bids are invited for khajuraho airport sitc of spd 40 ka spd for ccr in , sitc of spd 480 ka spd for ccr out , insulating mat 2.00 mm 3.3 kv , insulating mat 3.00 mm 33 kv , gsm based auto dialer , sitc of fire panel , sitc of smoke detector , sitc of manual call point , sitc of 2x1 .5 sqm fire alarm cable , sitc of horn cum strobe provision of spd in ccr and other electrical works at total quantity : 250...

Indian Army - Madhya Pradesh

40461580 bids are invited for wireless anti intrusion system and wireless smoke detector system incl installation total quantity : 1...

General Administration Department - Madhya Pradesh

40384392 bids are invited for supply installation testing and commissioning of fps system for dccb morena common control panel with indications , jockey pump set 03 phase required 70 m head , main fire fighting pump set 03 phase required , diesel driven pump set of required 70m head , 150 mm , 100 mm , 80 mm , 50 mm , 25 mm , pressure switch , pressure gauge , butterfly valve , dual plate check valve wafer , two way fire brigade inlet , swinging compact type first aid hose reel , valve with ss ball , valve brass forged , 150 mm , 100 mm flow switch , air release valve , spring type pressure release valve , powder coated double door hose box size , single way landing valve , coupling with gi wire , short branch pipe 63 mm dia , pendent type automatic sprinkler 680 centigrade , hooter , addressable input output mode , hydraulically operated sprinkler alarm unit , armored cable , cooper flexible cable , automatic dual led smoke detector , automatic dual led heat detector , 2 loop micro processor based intelligent , indoor addressable manual break glass unit , indoor stand alone loop powered detector , safety signage , ms air vessel fabricated , first aid fire extinguisher 6kg , first aid fire extinguisher , mechanical foam , core cutting charges , structural steel total quantity : 2739...

Medical Education Department - Madhya Pradesh

40104318 bids are invited for boq bid abc type fire extinguisher cylinder 6 kg , clean agent 2 kg fire extinguisher wall mount , clean agent 4 kg fire extinguisher wall mount , fire alarm panel 4 zone wireless , smoke detector wireless , hooter , mcp manual call point wireless , installation charges , nozzle for hydrant pipe , hydrant pipe with connector , 9 hp motor and starter repair with fire control panel total quantity : 333...

General Administration Department - Madhya Pradesh

39910593 bids are invited for supply installation testing and commissioning of bcfa system for dccb morena galaxy 4 zone 4016 gsm control panel , battery , panic switch , magnetic contact 4 wire , heavy duty shutter contact , sounder 12v , internal sounder , quad p.i.r. motion sensor , multi function detector , photoelectric smoke detector , rate of rise heat detector , manual call point , response indicator , cable , installation charges total quantity : 4408...

Department Of Housing And Urban Development - Madhya Pradesh

39689169 bids are invited for fire alarm system in third floor in vidhan sabha active and networkable repeater panel , 24 awg hi addressable automatic dual led smoke detector , sitc oindoor addressable manual break glass unit , indoor standalone loop powered detector base sounder , strobe for base , response indicator , fire survival cable total quantity : 4027...

Housing Department - Madhya Pradesh

39689158 bids are invited for sabha bhopal 4 loop microprocessor , loop card , active and networkable repeater panel , addressable automatic dual led smoke detector , indoor addressable manual break glass unit , indoor standalone loop powered etector base sounder , strobe for base , response indicator , fire survival cable fire alarm system in library and near by area in vidhan total quantity : 2406...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

39257287 tender for supply, installation and commissioning of it equipment’s for advanced metering infrastructure unified command control centre ( uccc ) at mpmkvvcl, bhopal 1 led commercial tv 2 switch with rack 3 laying of lan cable with casing 4 creation of i/o points 5 laying of optical fibre line from dc to scada 6 laying of telephone lines with casing 7 10 kva ups + 12v 100 ah 40 nos. smf lead acid battery bank 8 ip camera 9 poe switch 8 port manageable for ip cameras 10 smoke detector satellite only 11 fire extinguisher 5 litre 12 public address satellite/speaker roof mounted 13 split ac 2 ton inverter 5 star 14 wall fan 15 white wash walls 16 water proofing of walls 17 water proofing of roof 18 glass/wooden partition cabins 19 installation of led lights 2x2 roof panels 20 window blinds of size 5ft. x 4ft. approx. 21 white wash walls ...

Indian Army - Madhya Pradesh

39173723 bids are invited for wireless anti intrusion system and wireless smoke detector system incl installation (q3) mse total quantity : 1...

West Central Railway - Madhya Pradesh

39031578 supply of set of non metallic pipe ( smoke detector pipe ) each set consist of 15 items clw cat no. p / 0 / 00 / 41 c&d no. t028 / 705 as per drg. no. 29230020 alt.a as per specn. clw / es / 3 / 0254 alt b. or latest. [ warranty period: 30 months after the date of delivery ] => limited...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

38572650 restoration of co2 fire protection system of generator installed at 1x20 mw birsinghpur hydel power station birsinghpur , supply material , panel co2 flooding system 02 tone , smoke detector , co2 extinguisher dischare hose pipe , co2 extinguisher valve , pneumatic valve , co2 fireextinguisher refilling charges ( cap. 45 kg. ) , hydraulic testing of co2 fireextinguisher ( cap. 45 kg. ) , mcp release , mcp abort , hooter , nrv , loop hose pipe small cylinder to cylinder , nitrogen cylinder capacity 4 / 5 kg , solenoid valve , pressure gauge , hardware items. ( including pipe, band etc. ) , copper armoured cable 02 core 1.5 mm , work part , transportation & handling charges ( for 36 no. fire extingusher cylinder ) , services charges including handling, painting, engineering, design & assembly and commissioning...

National Fertilizers Limited - Madhya Pradesh

37351993 annual rate cotract for misc instrument maintenance jobs for the year 2023 24. 1 level measuring instruments 2 removing of level gauges ( pr. rating < 40 kg / cm2 ) 3 fixing of level gauges ( pr. rating < 40 kg / cm2 ) 4 removing of level gauges ( pr. rating > 40 kg / cm2 ) 5 fixing of level gauges ( pr. rating > 40 kg / cm2 ) 6 removing of level switches ( pr. rating < 40 kg / cm2 ) 7 fixing of level switches ( pr. rating < 40 kg / cm2 ) 8 removing of level switches ( pr. rating > 40 kg / cm2 ) 9 fixing of level switches ( pr. rating > 40 kg / cm2 ) 10 removing oflevel troll ( pr. rating < 40 kg / cm2 ) 11 fixing oflevel troll ( pr. rating < 40 kg / cm2 ) 12 removing oflevel ttroll ( pr. rating > 40 kg / cm2 ) 13 fixing oflevel troll ( pr. rating > 40 kg / cm2 ) 14 removing of level controller ( local ) / transmitter 15 fixing of level controller ( local ) / transmitter 16 removing of level transmitters ( purge type ) 17 fixing of level transmitters ( purge type ) 18 removing of level dp transmitter with / without capillary 19 fixing of level dp transmitter with / without capillary 20 removing of ultrasonic / radar / capacitance type level transmitter with accessories 21 fixing of ultrasonic / radar / capacitance type level transmitter with accessories 22 level gauge module removal ( on line ) for high pressure gauges 23 level gauge module fixation ( on line ) for high pressure gauges 24 removal of electrode of hydrastep ( l.g ) 25 fixation of electrode of hydrastep ( l.g ) 26 assistance in removal of nuclear type level instt. 27 assistance in fixing of nuclear type level instt. 28 removal of local float & rope type indicaters 29 fixation of local float & rope type indicaters 30 removal & cleaning of purge tube / dip tube of level transmitter 31 fixation of purge tube / dip tube after cleaning 32 changing of gauge glass / mica sheet / gaskets of lgs 33 pressure measuring instruments 34 removing of pressure gauges ( ordinary ) ( all sizes & ratings ) 35 fixing of pressure gauges ( ordinary ) ( all sizes & ratings ) 36 removing of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 37 fixation of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 38 removing of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 39 fixation of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 40 removing of pressure switches all types / sizes 41 fixing of pressure switches all types / sizes 42 removing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 43 fixing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 44 removing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 45 fixing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 46 removing of pr.controller ( electronic ) ( local panel mounted ) 47 fixing of pr.controller ( electronic ) ( local panel mounted ) 48 removing of air pr. regulators any size / rating 49 fixingof air pr. regulators any size / rating 50 removing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 51 fixing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 52 level measuring instruments 53 removing of purge / on line rotameters of all sizes / ratings 54 fixing of purge / on line rotameters of all sizes / ratings 55 removing of dp type flowmeter electronic / pneumatic ( without seal ) 56 fixing of dp type flowmeter electronic / pneumatic ( without seal ) 57 removing of dp type flowmeter electronic / pneumatic ( with seal ) 58 fixing of dp type flowmeter electronic / pneumatic ( with seal ) 59 removal of turbine flowmeter 60 fixingof turbine flowmeter 61 removal of electro magnetic type flowmeter 62 fixingof electro magnetic type flowmeter 63 removing of dpi / dp type local flowmeter 64 fixing of dpi / dp type local flowmeter 65 removing of pitot tube / annubar of any size / rating 66 fixing of pitot tube / annubar of any size / rating 67 removing of flow switches for line size upto 2 68 fixing of flow switches for line size upto 2 69 removing of flow switches for line size > 2 70 fixing of flow switches for line size > 2 71 temperature measuring instruments 72 removing of the thermo couple / rtd elements ( single, duplex, triplex ) including elecrical termination 73 fixing of the thermo couple / rtd elements ( single, duplex, triplex ) including electrical termination 74 removing of the temperature recorder / indicator / monitor from panel 75 fixing of the temperature recorder / indicator / monitor from panel 76 removing of local temperature gauge ( bimettalic / filled ) with mounting 77 fixing of local temperature gauge ( bimettalic / filled ) with mounting 78 removing of temperature switch including electrical termination 79 fixing of temperature switch including electrical termination 80 removing of capillary filled type local temperature gauge with mounting 81 fixing of capillary filled type local temperature gauge with mounting 82 removal of thermowell of all sizes & ratings 83 fixingof thermowell of all sizes & ratings 84 analysers 85 removing and cleaning of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 86 fixing back of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 87 removing and cleaning of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 88 fixing of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 89 removal and cleaning of chlorine detectors including accessories 90 fixing of chlorine analyser detectors including accessories 91 removal and cleaning of chlorine ejector 92 fixing of chlorine ejector 93 removal and cleaning of chlorine regulator 94 fixing of chlorine regulator 95 removing, cleaning & tightening of water analyser sampling system components 96 removing and cleaning of ph analyser filters & fixing them back 97 removing of calibration gas cylinders with regulators & connections 98 fixing of calibration gas cylinders with regulators & connections 99 removing of gas regulators from gas cylinders 100 fixing of gas regulators from gas cylinders 101 removal of damaged sample cooling coil, repair / fabrication of new coil from 6mm ss tube & mounting of same in sample cooler 102 impulse line piping for transmitters 103 laying, fabrication, erection & testing including required cutting, fitting & welding jobs for following pipe size / rating: 104 size 1 / 2 carbon steel, non ibr sch 40 105 size 1 / 2 carbon steel, non ibr sch 80 106 size 1 / 2 carbon steel, non ibr sch 160 107 size 1 / 2 stainless steel, non ibr sch 40 / 80 108 size 1 / 2 stainless steel, non ibr sch 160 109 size 1 / 2 alloy steel, non ibr sch 40 110 size 1 / 2 alloy steel, non ibr sch 80 111 size 1 / 2 alloy steel, non ibr sch 160 112 size 1 / 2 alloy steel, ibr sch 40 113 size 1 / 2 alloy steel, ibr sch 80 114 size 1 / 2 alloy steel, ibr sch 160 115 size 1 carbon steel, non ibr sch 40 / 80 116 size 1 stainless steel, non ibr sch 40 / 80 117 size 2 carbon steel, non ibr sch 40 / 80 118 size 2 stainless steel, non ibr sch 40 / 80 119 removal of pipingwith supports including cutting for all sizes irrespective of pipe material & rating 120 laying & testing of gi pipe including cutting, fitting & welding jobs for following pipe sizes: 121 size 1 / 2 122 size 1 123 size 2 124 removal of gi pipe with supports including cutting for all sizes 125 arrest the leakage of a joint by welding / rewelding of joint / welding of crack or broken parts 126 for carbon steel material & all rating 127 for stainless steel material & all rating 128 removal of condensate pots including related cutting 129 fixing of condensate pots including cutting & welding 130 fabrication & installation of float guide upto 4 pipe 131 tubing jobs ( including connections & testing ) 132 size 6mm s.s. / copper tube laying 133 size 6mm s.s. / copper tube removing 134 size 8mm s.s. / copper tube laying 135 size 8mm s.s. / copper tube removing 136 size 10mm s.s. / copper tube laying 137 size 10mm s.s. / copper tube removing 138 size 12mm s.s. / copper tube laying 139 size 12mm s.s. / copper tube removing 140 cabling jobs: cable laying on cable tray / trench / conduits, glanding, termination & checking of cables for loop continuity. removing of cables from cable trays / trench / conduits including electrical terminations and storing them with proper marking. cable types: signal, power, control, thermocouple, rtd cables conductor size =<0.5mm2 ( armoured / unarmoured ) , optical fiber cable for cctv. 141 laying of cable, 2 core to 6 core 142 removing of cable, 2 core to 6 core 143 laying of cable, 7 core to 24 core 144 removing of cable 7 core to 24 core 145 fixing of junction box complete with accessories ( area<=500 cm2 ) 146 removal of junction box disconnecting electrical cables ( area<=500 cm2 ) 147 fixing of junction box complete with accessories ( area>500 cm2 ) 148 removal of junction box disconnecting electrical cables ( area>500 cm2 ) 149 digging 300mm wide 0.5 m deep trench, laying of bricks & filling back with sand / earth after laying the cable 150 laying conduit / gi pipe=<2through the trench 300mmwide 0.5m deep 151 dressing of the cables ( 2 to 24 core ) with proper clamping 152 removal of broken bolts of jb covers & fixing new bolts. 153 replacement of cable gland / pipe fitting / tube fitting, where cable laying / pipe laying / tube laying is not desired. size upto 2 and all rating & material. 154 laying of optical fiber cable 155 removing of optical fiber cable 156 crimping / splicing of optical fiber cable pieces 157 tray & other misc. jobs tray / angle iron laying ( for tubing / cables ) fixing of supports including related cutting, welding, fitting jobs for different sizes: 158 size : 2 / 50 mm wide 159 size : 4 / 100 mm wide 160 size : 8 / 200 mm wide 161 size : 16 / 400 mm wide 162 al. tray cover fixation size 200 mm. 163 al. tray cover fixation size 400 mm. 164 tray / angle iron removing ( for tubing / cables ) including related cutting & grindingjobs for different sizes: 165 size : 2 / 50 mm wide 166 size : 4 / 100 mm wide 167 size : 8 / 200 mm wide 168 size : 16 / 400 mm wide 169 al. tray cover removal size 200 mm. 170 al. tray cover removal size 400 mm. 171 fabrication / re conditioning & erection of gi / ms sheet canopies / protection covers for transmitters / other instruments of size upto 1 sq m. area 172 fabrication of supports of structural steel 173 fabrication of stanchions for mounting insts. as per standards 174 dismentling of structure by opening bolts, gas cutting, removal & shifting from site to scrap stores 175 removing of canopy / protection cover for maintenance job of instrument and fixing back ( any size ) 176 isolation valves & gland packing jobs fixing of isolation valves ( socket weld / threaded type ) including fitting, welding & pressure testing job for following sizes : 177 size 1 / 4, upto 1500# lbs rating cs / ss 178 size 1 / 2, 1500# 3000# lbs rating cs / ss 179 size 1, 1500# 3000# lbs rating cs / ss 180 size 2, 1500# 3000# lbs rating cs / ss 181 removal of isolation valves ( socket weld / threaded type ) including fitting, cutting job irrespective of material, rating & upto size 2 inclusive 182 gland packing of isolation valves / control valves of any sizes 183 opening of flanges, cleaning, repair & polishing of gasket surfaces ( including lapping of ring / lens joint type ) and boxing up as & when required. size upto 4 and all ratings 184 dismentaling, cleaning and assembling of condensate drain system in passivation air comprs. ( k 3 ) 185 control valve jobs 186 opening of control valve from actuator / bonnet / line upto 2 size & any rating 187 opening of control valve from actuator / bonnet / line upto 3 size & any rating 188 opening of control valve from actuator / bonnet upto 4 size & any rating 189 opening of control valve from actuator / bonnet upto 5 & 6 size & any rating 190 opening of control valve from actuator / bonnet upto 8 & 10 size & any rating 191 opening of control valve from actuator / bonnet above 10 size & any rating 192 fixing back of control valve actuator / bonnet on the body / line upto 2 size & any rating 193 fixing back of control valve actuator / bonnet on the body / line upto 3 size & any rating 194 fixing back of control valve actuator / bonnet on the body upto 4 size & any rating 195 fixing back of control valve actuator / bonnet on the body upto 5 & 6 size & any rating 196 fixing back of control valve actuator / bonnet on the body upto 8& 10 size & any rating 197 fixing back of control valve actuator / bonnet on the body above 10 any rating 198 removal of valve positioner with its pneumatic / electrical connection 199 removal of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 200 removal of volume booster alongwith its pneumatic connection 201 removal of i / p convertor alongwith pneumatic / electrical connection 202 removal of solenoid valve alongwith pneumatic / electrical connection 203 fixing of valve positioner alongwith pneumatic / electrical connection 204 fixing of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 205 fixing of volume booster alongwith its pneumatic connection 206 fixing of i / p convertor alongwith its pneumatic / electrical connection 207 fixing of solenoid valve alongwith pneumatic / electrical connection 208 replacement of actutor diapragm ( pneumatic ) of any size actuator 209 removal of piston / power cylinder alongwith pneumatic connection 210 fixing of piston / power cylinder alongwith pneumatic connection 211 lapping of plug , seat & other sealing surface of control valves 212 greasing of control valve parts 213 removal of air filter regulator set with fittings 214 fixingof air filter regulator set with fittings 215 jobs in bagging plant area 216 removal and cleaning of level probes & refixing 217 cleaning of machines, weigh pans, solenoid valves, power cylinders etc. 218 replacement of broken weigh pan assembly of bagging machines & repairing by doing necessary cutting / welding, cleaning etc. 219 cleaning of avery / tulaman pre determined weighing scales ( check weighers ) 220 cleaning of et 6 belt weighers framework and related equipments 221 assistance in calibration of bagging machines by putting weights 222 fixing of power cylinder of piston dia.upto 100mm on the machine 223 removing of power cylinder of piston dia.upto 100mm from machine 224 removal of solenoid valve spool type 5 ports 225 fixing of solenoid valve spool type 5 ports 226 laying / removing pvc / nylon tubing upto 12mm size 227 filling of oil in bagging machine air regulators 228 replacement of proximity sensor in pandoor / bagholder of bagging machines 229 replacement & repairing of broken feed gate assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 230 removing, cleaning & fixing of anti vibration pads in bagging machines 231 replacement & repairing of brokenbag holder assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 232 replacement of load cell ( including all accessories ) of urea bunker level measuring system / urea belt weigher / weigh bridges 233 other misc.jobs 234 removing of manual call points mcp ) including accessories 235 refixing of manual call points mcp ) including glanding and termination 236 removing of heat, flame or smoke detectors & termination 237 refixing of heat, flame or smoke detectors & termination 238 painting of control valves, actuators including accessories & other insts. with mounting stand 239 writing of tag nos. on instruments, control valves, etc 240 cleaning of instruments, control valves, local panels, ccr cabinets etc 241 laying of heat detector cable on cable trays & their connections 242 removing of heat detector cable on cable trays 243 removal of speed / vibration / axial displacement probe / extension cable 244 fixation of speed / vibration / axial displacement probe / extension cable 245 removal of field tachometer / speed indicator 246 fixation of field tachometer / speed indicator 247 control panel cutting ( for cable entry or providing new instrument ) 248 removal of low explosive limit detector / ammonia detector / co detector 249 fixation of low explosive limit detector / ammonia detector / co detector 250 transportation of instruments / materials from respective plant to instrument workshop / store 251 transportation of instruments / materials from instrument workshop / store to respective plants 252 removal of uv flame scanner & cleaning 253 fixation of uv flame scanner 254 removal of weephole probe in urea reactors 255 fixing of weephole probe in urea reactors 256 removal, cleaning / washing and fixing of suction air filters of ccr / lcr control cabinets ( dcs / esd / ops / his / vms & printer consoles ) 257 panel cooling fans removing, cleaning & checking 258 panel cooling fans fixing ( including mounting arrangement ) 259 various plant jobs: to assist nfl employees in executing various instrument maintenance jobs in routine day to day maintenance in general shift, central shift. ( 8 hrs of normal working ) mandays for sr no 14.01 14.02, 1. bidder has to ensure due diligence to comply with statutory obligations as nit clause of stc ( annexure xiv ) 2. price bids will be rejected if the quoted rate is found less than the notified minimum wages for unskilled / skilled workers applicable as on 01.04.2023 plus statutory obligation @ 32.91%of the applicable minimum wages as on 01.04.2023 to comply statutory obligations. reference calculation for item s.no 14 ( 14.01 14.02 ) are as under: ( minimum 32.91% ) ( 8 hrs of normal working ) ( 1 ) minimum wages for helper ( unskilled ) = 494 + 162.58= 656.58 ( 2 ) minimum wages for skilled manpower =695 + 228.72=923.72quoted rateshall not be less than minimum amount as mentioned above. 260 helper ( un skilled ) 261 manpower ( skilled ) 262 ot hours : to assist nfl employees in executing various instrument maintenance jobs during unforeseen breakdown / short shutdown & emergency requirement. ( beyond 8 hrs of normal working ) .refernce calculation included esi @3.25% on minimum wage as on 01.04.2023 for items under s.no 15 & 17 are as under: ( 1 ) minimum wages for helper ( unskilled ) = ( 494+16.06 ( esic ) / 8 ) *2= 127.51. ( 2 ) minimum wages for skilled manpower = ( 695+22.59 ( esic ) / 8 ) *2= 179.40.party shall be paid above fixed rate without any service charge as per clause 1 ( ii ) of stc & tc annexure xiv. 263 helper ( un skilled ) 264 manpower ( skilled ) 265 planned shutdown: supply of contract labour for planned shutdown of line i & line ii. ( 8 hrs of normal working ) mandays for sr no 16.01 16.06, 1. bidder has to ensure due diligence to comply with statutory obligations as per nit clause of stc ( annexure xiv ) .2. price bids will be rejected if the quoted rate is found less than the notified minimum wages for unskilled / skilled workers applicable as on 01.04.2023 plus statutory obligation @ 16.25% of the applicable minimum wages as on 01.04.2023 to comply statutory obligations. refernce calculation for item s.no 16 ( 16.01 to 16.06 ) are as under: ( minimum 16.25% ) ( 8 hrs of normal working ) ( 1 ) minimum wages for helper ( unskilled ) = 494 + 80.28 = 574.28. ( 2 ) minimum wages for skilled manpower =695 +112.94 = 807.94.quoted rateshall not be less than minimum amount as mentioned above. 266 helper ( un skilled ) 267 fitter ( skilled ) 268 rigger ( skilled ) 269 welder ( skilled ) 270 electrician ( skilled ) 271 technician ( skilled ) 272 ot hours : supply of contract labour for planned shutdown of line i & line ii. ( beyond 8 hrs of work ) . party shall be paid fixed rate without any service charge as mentioned at sl. no. 15 above as per clause 1 ( ii ) of stc & tc annexure xiv. 273 helper ( un skilled ) 274 fitter ( skilled ) 275 rigger ( skilled ) 276 welder ( skilled ) 277 electrician ( skilled ) 278 technician ( skilled ) ...

Urban Development Department - Madhya Pradesh

36831476 bids are invited for false ceiling work 1 title 1 providing and fixing false ceiling tiles of approved materials of size 595 x 595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm / sqm. ) consisting of main t runner suitably spaced at joints to get required length and of size 24x38mm made from 0.30mm thick ( minimum ) sheet spaced at 1200mm center to center and cross t of size 24x25mm made of 0.30mm thick ( minimum ) sheet, 1200mm long spaced between main t at 600mm center to center to form a grid of 1200x600mm and secondary cross t of length 600mm and size 24x25mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm gi adjustable rods with galvanised level clips spaced at 1200m center to center along main t, bottom exposed width of 24mm of all tsections shall be pre painted with polyester paint, all complete at all heights as per specifications drawings and as directed by engineer in charge. ( the rate is excluding cost of tiles which will be paid separately ) 600 square meter 2 title 2 providing and fixing false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of bwp type phenol formaldehyde synthetic resin bonded pressed particle board conforming to is:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face to be fixed on a grid made out of anodised aluminium ( with 15 micron anodic coating ) t sections 35x15x1.5 mm size main runners and cross runners 23.5x19x1.5mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. the frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia m.s rod fixed to roof slab by means of ceiling cleats. the suspenders shall be placed 600x1200 mm centre to centre including fixing to the frame with c.p brace screws and applying a priming coat of zinc chromate yellow primer ( aluminium frame work shall be paid separately ) . 600 square meter 3 title 3 extra for providing 3mm thick translucent white acrylic plastic sheets of approved quality in false ceiling instead of 12 mm thick plain / or with design particle board ceiling tiles in item above. 600 square meter 4 title 4 4 mm thick aluminimum acomposite pannel material consisting of 3 mm thick fr grade mineral core sandwiched between two alumminium sheets ( each 0.5mm thick ) 262 square meter 5 title 5 supplying and fixing surface mounting led down lighter, ledof 1 to 3 w each assembled on single mcpcb, having colortemp 6500k & having 50000 burning hrs life with minimum@ l 70, system lumen output should be minimum withefficacy>80lm / w. led driver pf 0.95 & thd < 20%. thecolour rendering index of led light should be more than 70.housing made of crca powder coated frame with glare freediffused polycarbonate cover. submission lm 80 08 formled source manufacturer & lm79 08 / is16106 from nablapproved lab. manufacturer mandatory. i / c connection wire, testing etc. to complete the job. 2 yrs guarantee certificate from manufacturer. 15 w , 180 / 200mm...

Department of Higher Education - Madhya Pradesh

36520730 bids are invited for microprocessor based addressable fire alarm system fire alarm pamel , smoke detector , heat detector , mcp , sounder , safety device , monitor module , control module , armured cable total quantity : 2397...

Department Of Environment - Madhya Pradesh

36364993 bids are invited for 2 loop microprocessor , loop card , title3 active and networkable repeater panel , addressableoptical detector , addressable automatic dual led smoke detector , indoor addressable manual break glass unit , indoor standalone loop powered detector base sounder , strobe for base , response indicator , fire survival cable total quantity : 730...

Capital Project Administration - Madhya Pradesh

36364813 bids are invited for eprocurement 1 2 loop microprocessor , title2 loop card , title3 active and networkable repeater panel , title4 addressableoptical detector , title5 addressable automatic dual led smoke detector , title6 indoor addressable manual break glass unit , title7 indoor standalone loop powered detector base sounder , title8 strobe for base , title9 response indicator , title10 fire survival cable total quantity : 811...

Military Engineer Services - Madhya Pradesh

35933883 tender for comprehensive maintenance of fire fighting system fire alarm system smoke detectors other associated works in fire fighting systems and repair maint of pumpset filtration plant cleaning of pool and other connected works under ge maint inf school...

Ministry Of Power - Madhya Pradesh

35182163 bids are invited for sagar power station base of heat and smoke detector supply siga sb base of heat and smoke detector at indira total quantity : 200...

National Thermal Power Corporation Limited - Madhya Pradesh

34891896 supply of utc fire and security equipments for stage 1 of ntpcvindhyachal stps fire fighting spares: est intelligent duct smoke detector: siga sd, multi sensor type detector model: nfx smt2, single in put module siga ct1, control relay module model: siga cr, make edwards, control & instruments fire fighting instruments, item: manual call point ( mcp ) .model: siga 270, construction:cast zinc with steel back plate, operating mechanism:single ction pull lever, operating voltage: 15.2 to 19.95v dc, stdby.current: 250 micro mp, activated current: 400 micro amp, operating temp: 0 to 49 deg c., remote fire alarm repeater panel model: 3 lcdann, electronic horn ( hooter ) , 4901 9822, : etc...

National Thermal Power Corporation Limited - Madhya Pradesh

34617905 procurement of c and i instruments for fdps at ntpc vindhyachal , linear heat sensing cable(lhs cable) , 2/2 solenoid valve ,intrnlpilot operated , pressure switchrange: 1 16 bar , single input module siga ct1 , monitor module model: siga ct2; edward , control relay module: siga cr; edwards , multisensor smoke detector base siga phs , photoelectric smoke detector siga ps , manual call point (mcp),model: siga 270 , frp junction box 48 way, 425x420x150 mm , hooter for fire system u mh , control cable 2c x 1.5 sqm. fire alm&det , 2c x 2.5 sq.mm micc cable , cable frls armd,1.1kv,2c x 2.5 sqmm cu. , response indictr: sse drin hbs honeywell , cable 1.1kv pvc cu strnd 2cx1.5sqmm , limit switch: 2way,jai balaji jb 9 spls , infrd detector air purging system , lcp module, type:cp410m,make:advent abb , signal hooter type:3mh1007,110v ac , linear heat sensing cable(lhs cable) , 2/2 solenoid valve ,intrnlpilot operated , pressure switchrange: 1 16 bar , single input module siga ct1 , monitor module model: siga ct2; edward , control relay module: siga cr; edwards , multisensor smoke detector base siga phs , photoelectric smoke detector siga ps , manual call point (mcp),model: siga 270 , hooter for fire system u mh , control cable 2c x 1.5 sqm. fire alm&det , 2c x 2.5 sq.mm micc cable , cable frls armd,1.1kv,2c x 2.5 sqmm cu. , response indictr: sse drin hbs honeywell , cable 1.1kv pvc cu strnd 2cx1.5sqmm , limit switch: 2way,jai balaji jb 9 spls , infrd detector air purging system , lcp module, type:cp410m,make:advent abb , signal hooter type:3mh1007,110v ac , battery charger module: 3bbc/m 230 , cpu module: 3 cpu3; edwards , transceivers card: smxlo; edwards , communication rs232 card 3 rs232 , power supply module priamary of fap , cable tray pvc channel: 45x75mm , junction box: type jb f,size 100x150mm , pr gauge: 0 16kg/cm2,1/2npt(m) compound , fo cable 4 fiber , lead acid(p)battery bank: 12v, 65ah, smf , fbr.optic commn.card: 3 fibmb 2; edwards , pc based data logger,pt no.:gd384av,aaqm , signature loop intelligent contrlr card...

Ministry Of Petroleum And Natural Gas - Madhya Pradesh

34016543 bids are invited for smoke detector tester bottles make solo , aerosol smoke dispeser model 330 001 for smoke detector testing kit , telescopic pole fibre glass extendableupto 4.5 meters model 100 001procurement smoke detector testing kit aerosol total quantity : 105...

Bhopal Municipal Corporation - Madhya Pradesh

34009986 fire brigade impenalment tender 2022 23 fire brigade impenalment tender 2022 23 , impanelment of miscellaneous item for 2022 23 , type 3 hose pipe with coupling 63 mm dia 15mtr. length gun metal approx , hose reel 100 feet long , concord helmet , pvc helmet , gumboot all category , fireman axe , foam branch pipe compelete 5x , foam branch pipe compelete fb 10x with pick up tube 63 meter , short branch gun metal , short branch stainless steel , long branch , chhadi , tamy , portable fire extinguisher 1.5 kg , hydraulic jack 10 ton mechanical , jack simple 50 ton , suction pipe 3 inch 100 feet long , suction pipe 4 inch100 feet long , aluminium extension ledder with rope , staicher , electric saw cutter , petrol saw cutter , belcha , tagadi , hooter , wheel pana set , ring pana set , fix pana set , gaiti , lifebuoy tube , abc fire extinguisher 4kg , abc fire extinguisher 6kg , abc fire extinguisher 9kg , co2 fire extinguisher 4.5kg , fire extinguisher hydraulic testing , d watering pump handle , screw driver , lifejacket , nylon rope 1 inch thick per kg , nylon rope 1 / 2 inch thick per kg , manila rope 1 / 2 inch thick per kg , manila rope 1 inch thick per kg , kanta , jaal 5x10 , electric work per sq. ft. , ar afff 3% foam compound per ltr. , kulhadi , hammer , mega phone , male & female coupling set 63mm , revalving branch , gun metal hand control branch , snake catcher , multipana , fawda , pliers , suction hose raze pana , metal strainer 100 mm , chhaini , hose coupling lux set gun metal , hose bandage , hose clip , tool kit , aari , foam pickup tube , adjustable spanner , pipe hose clip 100 mm , pipe hose clip 80 mm , gas cutter , special foam for aska set , fire hooter , smoke detector , hose coupling female rubber 63’ , gas refilling of mortuary box , mortuary boxwheel , mortuary box display , compressor set oil filter , compressor set discharge filter , compressor set oil , mortuary box compressor , repairing charges of mortuary box , fire reflective jacket with logo , synthetic hose 15mtr. s.s. coupling , alluminium workper sq. ft. , hydraulic cutter battery , snake box wooden , armoured cable per meter , full fire mask , half fire mask , folding fabric straicher , water net , wire cutter , aluminum ledder 10ft. , gi box for ba set , gi box for proximity suit , snack caching hook , pacha , hose real nozzle , harness belt set , 100w led flood light , monkey pliers , nose pliers , rinch pana , sports shoes for snake cacher , track suit for divers , track suit for snake cacher , electric saw cutter chain , electric saw cutter patta , fire wooden table , compressor , pcb for mortury box , revolving office chair , electric saw machine repairing & servicing , wheel cutter machine , fire proximity suit 3 layer , fire entry suit 7 layer , b.a. set , hydraulic jack with trolly , cutting blades cc , foam generator , d watering pump 5hp , d watering pumpservicing , aska light service , fire motor boatengine service , fire electric generator service , b.a. compressor service , smoke extractor petrol , water tank 300ltr. , cutting blades wood , fire rain coat , hose reel dunlop rubber , fire man locker almirah per locker , new mortuary box , non return valve , water tank 1000ltr. , gun metal valve , concrete groove cutter , albo , socket , seal tap , plumbing t , nipple 1inch , nipple ½ inch with threading , m seal / pv seal / solvent , brass ball valve ½ inch , brass ball valve 1 inch , water tank 500ltr. , fire electric hose binding machine , hydrant adaptor , m.s. pipe , m.s. welding work per sq. ft. , ci foot valve 100 mm , ci foot valve 80 mm , ci flench 100 mm , ci flench 80 mm , ci hose coller 100 mm , ci hose coller 80 mm , fire jacket ( sweater ) , 25mm threaded nipple , pressure switch with socket , pressure gauge with anti corrosion technology with glycerine filled , fit ‘n’ forget butterfly valve , dual plate check valve water type , 6’’ swinging compact type first aid hose reel , 20 / 25 mm dia ball valve with ss ball , 04 zone fire alarm control pane , manual call point , fire man gloves , fire multi purpose nozzle , cutting blades m.s , fire suit , single headed hydrant valve , main control panel , main fire fighting pump , sitc of 100mm ms pipe ( qty may vary at the time of installation ) , abc fire extinguisher refilling 9kg , co2 fire extinguisger refilling 4.5kg , co2 fire extinguisger refilling 22.5kg , foam type fire extinguisger refilling 9 ltr , abc fire extinguisher refilling 4kg , abc fire extinguisher refilling 6kg...

Directorate Of Medical Education - Madhya Pradesh

33943699 bids are invited for abc fire extinguisher isi mark 6 kg , nonark isi mark and peso approved co2 4.5 kg , safety halmet without rachet , safety gloves 33 kva , safety shoes , full body safety belt , reflective belt vest , safety google 3 m , ear plug 3 m , digital clamp meter 2000 count , digital multimeter trms 6000 count , megohmmeter analog insulation tester battery powered , pressure switch , wire 1.5 sqmm in mtr , pvc conduit 20 mm , socket 0.5 inch , labour charge , servising of addressble loop panel ratecontract , loop clearance charge rate contract , servicing and replacement of mcp rate contract , servicing and replacement of smoke detector ratecontract , servicing and replacement of hooterrate contract , wiring continuty checking chargerate contract , wiring and rewiring of armouredcable rate contract , battery 12 v and 9 ah ratecontract total quantity : 421...

Ministry Of Petroleum And Natural Gas - Madhya Pradesh

32843434 bids are invited for smoke detector tester bottles (q3) , aerosol smoke dispeser, model: 330 001 for smoke detector testing kit (q3) , telescopic pole, fibre glass,extendable upto 4.5 meters, model: 100 001 (q3) total quantity : 105...

Gas Authority Of India Limited - Madhya Pradesh

32783655 procurement of smoke and heat detector procurement of smoke and heat detector combo testing kit with standard accessories through nic portal , detector test kit for smoke and heat with universal removal tool ( for further details refer section v: technical specification of the tender document ) addl description: specification for smoke and heat detector test kit 1. the kit should be capable of testing smoke and heat detector at a height and at below floor level also. one kit to be used for both smoke and heat detectors. the option for detector to be tested i.e. smoke or heat should be selectable from a digital keypad with display. 2. detector kit should be suitable for use on smoke and heat detectors of both conventional and addressable types. 3. the kit should include a universal detector removal tool which is capable of removing all types of generally available smoke detectors. the detector removal tool should be easy to mount on extension pole to reach approx. 9 meters of height. it should be adjustable to cater to different diameters of detectors. 4. extension pole should be adjustable and should reach around 9 meters height. pole will be of light weight but good quality fiber material to bear the load of detectors testing kit. 5. a dispenser should be there to hold the smoke detector tester on the extension head in such a way that spray should not disperse out of dispenser. it should be easy to mount and easy to disassemble. 6. dispenser should be clear cup transparent type which allows the view of detector led. 7. smoke detector tester should be non flammable, nontoxic, and environment friendly. 8. it should be oil; free formulation and there should be no lasting residue 9. it must be ul certified. 10. since it is an important item, party must provide spares & service to gail india ltd. as per our requirement. 11. the kit should be supplied with standard accessories like smoke capsules, battery batons and chargers , adjustable extension poles for reaching detectors at approx. 9 meters height, carry and storage bag for both accessories and extension poles etc. the following item (includes smoke/heat/co kit are) to be supplied 01. smoke detector testing kit should have # solo fiber glass 2 section telescopic pole 4.5 meter 01 nos # solo 200 001 detector removal (universal detector removal) 01nos # solo 330 001 aerosol smoke & co dispenser 01 nos 02. heat detector test kit (solo 461 101 cordless) o1 set should have # 1xsols 460 001cordless heat head unit 01 # 2xsolo 760 001 battery baton 01 # 1x solo 725 001 fast charger 01 03. aerosals should have # solo a3 001 detector tester 250ml 06 nos # solo c3 001 co testing for co fire detector 06 nos # solo a7 001 clearing smoke detector 06nos 04. protective carrying / storage bag: 01no....

West Central Railway - Madhya Pradesh

32706289 supply of smoke detector unit .smoke detector unit .,smoke detector unit and fire alarm system complete with all accessories conforming to rcf specification no. edts 087 rev.b 1 suitable for lhb power cars....

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31625320 procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa , est3 power supply ( 3 pps / m 230 ) , power supply for edward make panel, hsn / sac code: 85311090 , est3 960 character lcd display ( 3 lcdxl1 ) , display board for edward make panel, hsn / sac code: 85311090 , est3 rs232 card ( 3 rs232 ) , rs 232 card for edward make panel, hsn / sac code: 85311090 , est3 dual loop card ( 3 sddc1 ) , dual loop card for edward make panel, hsn / sac code: 85311090 , est3 fiber optic interface module 3 fibmb2, fiber optic network card for edward make panel, hsn / sac code: 8531 , est3 fiber ( smxlo2 ) , communication module for edward make panel one panel need two nos incase both end is in fiber connectivity, hsn / sac code: 8531 , est optica multi detector siga ohsd, hsn / sac code: 8531. , est optica smoke detector siga osd, hsn / sac code: 8531. , est isolator base ( siga ib ) , hsn / sac code: 85311090. , est heat detector ( siga hrd ) , siga hrs is absolute and new model is back to back compatible with old panel hsn / sac code: 85311090 , est monitor module ( siga ct1 ) , hsn / sac code: 85311090. , est control module ( siga cr ) , hsn / sac code: 85311090. , est3 control relay module ( siga cc1 ) , hsn / sac code: 85311090 , est manual call point ( siga 278 ) , sigi271 is not ul & fm listed product so we have quoted dual stage which is higher specks and resettable through key, hsn / sac code: 85311090. , est hooter cum strobe ( g1avrf ) , quoted edward make ul / fm listed product led strobe, hsn / sac code: 85311090. , edward probe type detector 302 epm 135 ( ul / fm listed ) hsn / sac code: 8531 , flameproof junction box for probe type heat detector and module installation, hsn / sac code: 8535 , flameproof gland double compressor gland, hsn / sac code: 7318. , est weather proof manual call point ( mpsr2 s45w ) ( ul / fm listed ) , hsn / sac code: 85311090 , est standard base ( siga sb ) hsn / sac code: 85311090 , response indicator, hsn / sac code: 8535....

West Central Railway - Madhya Pradesh

31469091 supply of smoke detector and fire alarm system .smoke detector and fire alarm system .,smoke detector and fire alarm system conforming to rcf specification no edts 087 rev.b i. or latest....

West Central Railway - Madhya Pradesh

31154407 supply of smoke detector and fire alarm system .smoke detector and fire alarm system .,smoke detector and fire alarm system conforming to rcf specification no edts 087 rev.b i. or latest....

Military Engineer Services - Madhya Pradesh

31084703 spl repair of 12 x rolling shutters, roof treatment of bldg no. dm 09, provn of 05 geysers , fire alram and smoke detector spl repair of 12 x rolling shutters, roof treatment of bldg no. dm 09, provn of 05 geysers , fire alram and smoke detector at dronachal top bhopal...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

30490985 design, supply, erection, testing and commissioning of co2 gas flooding system for hydro generator protection system including supply of material required for renovation of co2 gas flooding system at 3x20 mw bhps iii deolond. design, supply, erection, testing and commissioning of co2 gas flooding system for hydro generator protection system including supply of material required for renovation of co2 gas flooding system at 3x20 mw bhps iii deolond. , painting of the co2 system with two coat of post office enamel red paint over one coat of red oxide primer etc complete in all respect. , seamless cylinders, ccoe approved capacity 36 kg complete in all respect of any existing cylinder failed in tests ( on actual basis) , refilling of co2 gas with 99.9% purity, each cylinder gas capacity 36 kg. , co2 cylinder bank along with weighing device mounting rail (suitable for 9 nos. of 36 kg capacity co2 cylinders) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , slave valve with pneumatic actuator & manual lever , non return valve suitable for fixing at co2 discharge header , high pressure discharge hose , high pressure pneumatic actuation hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve. , 32 nb co2 directional valve with pneumatic actuator & limit switch , 25 nb co2 directional valve with pneumatic actuator & limit switch , continuous gas monitor – led type , continuous gas weight monitor control panel suitable to connect 09 nos. of gas weight monitor common for all type of weight monitors. , manifold safety valve , pressure switch , discharge warning display unit , inhibit / abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working on 6 zone with 02 nos. spare , smoke detector/ probe type fixed temperature heat detector with junction , high pressure discharge nozzle with bowl , hydro test of seamless cylinders , installation, testing & commissioning of system...

Indian Army - Madhya Pradesh

30365972 bids are invited for wireless anti intrusion system and wireless smoke detection system including installation as per s.no (a) (i) of appendix a of rfp , wireless magnetic contact as per s.no (a) (ii) of appendix a of rfp , wireless pir detector as per s.no (a) (iii) of appendix a of rfp , wireless siren as per s.no (a) (iv) of appendix a of rfp , wireless smoke detector as per s.no (a) (v) of appendix a of rfp , wireless keyfob as per s.no (a) (vi) of appendix a of rfp , installation as per s.no (a) (vii) of appendix a of rfp total quantity : 1...

National Fertilizers Limited - Madhya Pradesh

30206468 annual rate contract of misc. instrumentation maintenance jobs at nfl vijaipur unit for the year 2021 22 ( a ) removing of level gauges ( pr. rating < 40 kg / cm2 ) 3 fixing of level gauges ( pr. rating < 40 kg / cm2 ) 4 removing of level gauges ( pr. rating > 40 kg / cm2 ) 5 fixing of level gauges ( pr. rating > 40 kg / cm2 ) 6 removing of level switches ( pr. rating < 40 kg / cm2 ) 7 fixing of level switches ( pr. rating < 40 kg / cm2 ) 8 removing of level switches ( pr. rating > 40 kg / cm2 ) 9 fixing of level switches ( pr. rating > 40 kg / cm2 ) 10 removing oflevel troll ( pr. rating < 40 kg / cm2 ) 11 fixing oflevel troll ( pr. rating < 40 kg / cm2 ) 12 removing oflevel ttroll ( pr. rating > 40 kg / cm2 ) 13 fixing oflevel troll ( pr. rating > 40 kg / cm2 ) 14 removing of level controller ( local ) / transmitter 15 fixing of level controller ( local ) / transmitter 16 removing of level transmitters ( purge type ) 17 fixing of level transmitters ( purge type ) 18 removing of level dp transmitter with / without capillary 19 fixing of level dp transmitter with / without capillary 20 removing of ultrasonic / radar / capacitance type level transmitter with accessories 21 fixing of ultrasonic / radar / capacitance type level transmitter with accessories 22 level gauge module removal ( on line ) for high pressure gauges 23 level gauge module fixation ( on line ) for high pressure gauges 24 removal of electrode of hydrastep ( l.g ) 25 fixation of electrode of hydrastep ( l.g ) 26 assistance in removal of nuclear type level instt. 27 assistance in fixing of nuclear type level instt. 28 removal of local float & rope type indicaters 29 fixation of local float & rope type indicaters 30 removal & cleaning of purge tube / dip tube of level transmitter 31 fixation of purge tube / dip tube after cleaning 32 changing of gauge glass / mica sheet / gaskets of lgs 33 pressure measuring instruments 34 removing of pressure gauges ( ordinary ) ( all sizes & ratings ) 35 fixing of pressure gauges ( ordinary ) ( all sizes & ratings ) 36 removing of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 37 fixation of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 38 removing of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 39 fixation of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 40 removing of pressure switches all types / sizes 41 fixing of pressure switches all types / sizes 42 removing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 43 fixing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 44 removing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 45 fixing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 46 removing of pr.controller ( electronic ) ( local panel mounted ) 47 fixing of pr.controller ( electronic ) ( local panel mounted ) 48 removing of air pr. regulators any size / rating 49 fixingof air pr. regulators any size / rating 50 removing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 51 fixing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 52 flow measuring instruments 53 removing of purge / on line rotameters of all sizes / ratings 54 fixing of purge / on line rotameters of all sizes / ratings 55 removing of dp type flowmeter electronic / pneumatic ( without seal ) 56 fixing of dp type flowmeter electronic / pneumatic ( without seal ) 57 removing of dp type flowmeter electronic / pneumatic ( with seal ) 58 fixing of dp type flowmeter electronic / pneumatic ( with seal ) 59 removal of turbine flowmeter 60 fixingof turbine flowmeter 61 removal of ovalgear type / mass flowmeter 62 fixingof ovalgear type / mass flowmeter 63 removal of electro magnetic type flowmeter 64 fixingof electro magnetic type flowmeter 65 removing of dpi / dp type local flowmeter 66 fixing of dpi / dp type local flowmeter 67 removing of pitot tube / annubar of any size / rating 68 fixing of pitot tube / annubar of any size / rating 69 removing of flow switches for line size upto 2 70 fixing of flow switches for line size upto 2 71 removing of flow switches for line size > 2 72 fixing of flow switches for line size > 2 73 removing of recorder from local / ccr panel 74 fixing of recorder from local / ccr panel 75 temperature measuring instruments 76 removing of the thermo couple / rtd elements ( single, duplex, triplex ) including elecrical termination 77 fixing of the thermo couple / rtd elements ( single, duplex, triplex ) including electrical termination 78 removing of the temperature recorder / indicator / monitor from panel 79 fixing of the temperature recorder / indicator / monitor from panel 80 removing of local temperature gauge ( bimettalic / filled ) with mounting 81 fixing of local temperature gauge ( bimettalic / filled ) with mounting 82 removing of temperature switch including electrical termination 83 fixing of temperature switch including electrical termination 84 removing of capillary filled type local temperature gauge with mounting 85 fixing of capillary filled type local temperature gauge with mounting 86 removal of thermowell of all sizes & ratings 87 fixingof thermowell of all sizes & ratings 88 analysers 89 removing and cleaning of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 90 fixing back of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 91 removing and cleaning of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 92 fixing of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 93 removal and cleaning of chlorine detectors including accessories 94 fixing of chlorine analyser detectors including accessories 95 removal and cleaning of chlorine ejector 96 fixing of chlorine ejector 97 removal and cleaning of chlorine regulator 98 fixing of chlorine regulator 99 removing, cleaning & tightening of water analyser sampling system components 100 removing and cleaning of ph analyser filters & fixing them back 101 removing of calibration gas cylinders with regulators & connections 102 fixing of calibration gas cylinders with regulators & connections 103 removing of gas regulators from gas cylinders 104 fixing of gas regulators from gas cylinders 105 removal of damaged sample cooling coil, repair / fabrication of new coil from 6mm ss tube & mounting of same in sample cooler 106 impulse line piping for transmitters 107 laying, fabrication, erection & testing including required cutting, fitting & welding jobs for following pipe size / rating: 108 size 1 / 2 carbon steel, non ibr sch 40 109 size 1 / 2 carbon steel, non ibr sch 80 110 size 1 / 2 carbon steel, non ibr sch 160 111 size 1 / 2 stainless steel, non ibr sch 40 / 80 112 size 1 / 2 stainless steel, non ibr sch 160 113 size 1 / 2 alloy steel, non ibr sch 40 114 size 1 / 2 alloy steel, non ibr sch 80 115 size 1 / 2 alloy steel, non ibr sch 160 116 size 1 / 2 alloy steel, ibr sch 40 117 size 1 / 2 alloy steel, ibr sch 80 118 size 1 / 2 alloy steel, ibr sch 160 119 size 1 carbon steel, non ibr sch 40 / 80 120 size 1 stainless steel, non ibr sch 40 / 80 121 size 2 carbon steel, non ibr sch 40 / 80 122 size 2 stainless steel, non ibr sch 40 / 80 123 removal of pipingwith supports including cutting for all sizes irrespective of pipe material & rating 124 laying & testing of gi pipe including cutting, fitting & welding jobs for following pipe sizes: 125 size 1 / 2 126 size 1 127 size 2 128 removal of gi pipe with supports including cutting for all sizes 129 arrest the leakage of a joint by welding / rewelding of joint / welding of crack or broken parts 130 for carbon steel material & all rating 131 for stainless steel material & all rating 132 removal of condensate pots including related cutting 133 fixing of condensate pots including cutting & welding 134 fabrication & installation of float guide upto 4 pipe 135 tubing jobs ( including connections & testing ) 136 size 6mm s.s. / copper tube laying 137 size 6mm s.s. / copper tube removing 138 size 8mm s.s. / copper tube laying 139 size 8mm s.s. / copper tube removing 140 size 10mm s.s. / copper tube laying 141 size 10mm s.s. / copper tube removing 142 size 12mm s.s. / copper tube laying 143 size 12mm s.s. / copper tube removing 144 cabling jobs: cable laying on cable tray / trench / conduits, glanding, termination & checking of cables for loop continuity. removing of cables from cable trays / trench / conduits including electrical terminations and storing them with proper marking. cable types: signal, power, control, thermocouple, rtd cables conductor size =<0.5mm2 ( armoured / unarmoured ) 145 laying of cable, 2 core to 6 core 146 removing of cable, 2 core to 6 core 147 laying of cable, 7 core to 24 core 148 removing of cable 7 core to 24 core 149 fixing of junction box complete with accessories ( area<=500 cm2 ) 150 removal of junction box disconnecting electrical cables ( area<=500 cm2 ) 151 fixing of junction box complete with accessories ( area>500 cm2 ) 152 removal of junction box disconnecting electrical cables ( area>500 cm2 ) 153 digging 300mm wide 0.5 m deep trench, laying of bricks & filling back with sand / earth after laying the cable 154 laying conduit / gi pipe=<2through the trench 300mmwide 0.5m deep 155 dressing of the cables ( 2 to 24 core ) with proper clamping 156 removal of broken bolts of jb covers & fixing new bolts. 157 replacement of cable gland / pipe fitting / tube fitting, where cable laying / pipe laying / tube laying is not desired. size upto 2 and all rating & material. 158 tray & other misc. jobs tray / angle iron laying ( for tubing / cables ) fixing of supports including related cutting, welding, fitting jobs for different sizes: 159 size : 2 / 50 mm wide 160 size : 4 / 100 mm wide 161 size : 8 / 200 mm wide 162 size : 16 / 400 mm wide 163 al. tray cover fixation size 200 mm. 164 al. tray cover fixation size 400 mm. 165 tray / angle iron removing ( for tubing / cables ) including related cutting & grindingjobs for different sizes: 166 size : 2 / 50 mm wide 167 size : 4 / 100 mm wide 168 size : 8 / 200 mm wide 169 size : 16 / 400 mm wide 170 al. tray cover removal size 200 mm. 171 al. tray cover removal size 400 mm. 172 fabrication / re conditioning & erection of gi / ms sheet canopies / protection covers for transmitters / other instruments of size upto 1 sq m. area 173 fabrication of supports of structural steel 174 fabrication of stanchions for mounting insts. as per standards 175 dismentling of structure by opening bolts, gas cutting, removal & shifting from site to scrap stores 176 removing of canopy / protection cover for maintenance job of instrument and fixing back ( any size ) 177 isolation valves & gland packing jobs fixing of isolation valves ( socket weld / threaded type ) including fitting, welding & pressure testing job for following sizes : 178 size 1 / 4, upto 1500# lbs rating cs / ss 179 size 1 / 2, 1500# 3000# lbs rating cs / ss 180 size 1, 1500# 3000# lbs rating cs / ss 181 size 2, 1500# 3000# lbs rating cs / ss 182 removal of isolation valves ( socket weld / threaded type ) including fitting, cutting job irrespective of material, rating & upto size 2 inclusive 183 gland packing of isolation valves / control valves of any sizes 184 opening of flanges, cleaning, repair & polishing of gasket surfaces ( including lapping of ring / lens joint type ) and boxing up as & when required. size upto 4 and all ratings 185 dismentaling, cleaning and assembling of condensate drain system in passivation air comprs. ( k 3 ) 186 control valve jobs 187 opening of control valve from actuator / bonnet / line upto 2 size & any rating 188 opening of control valve from actuator / bonnet / line upto 3 size & any rating 189 opening of control valve from actuator / bonnet upto 4 size & any rating 190 opening of control valve from actuator / bonnet upto 5 & 6 size & any rating 191 opening of control valve from actuator / bonnet upto 8 & 10 size & any rating 192 opening of control valve from actuator / bonnet above 10 size & any rating 193 fixing back of control valve actuator / bonnet on the body / line upto 2 size & any rating 194 fixing back of control valve actuator / bonnet on the body / line upto 3 size & any rating 195 fixing back of control valve actuator / bonnet on the body upto 4 size & any rating 196 fixing back of control valve actuator / bonnet on the body upto 5 & 6 size & any rating 197 fixing back of control valve actuator / bonnet on the body upto 8& 10 size & any rating 198 fixing back of control valve actuator / bonnet on the body above 10 any rating 199 removal of valve positioner with its pneumatic / electrical connection 200 removal of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 201 removal of volume booster alongwith its pneumatic connection 202 removal of i / p convertor alongwith pneumatic / electrical connection 203 removal of solenoid valve alongwith pneumatic / electrical connection 204 fixing of valve positioner alongwith pneumatic / electrical connection 205 fixing of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 206 fixing of volume booster alongwith its pneumatic connection 207 fixing of i / p convertor alongwith its pneumatic / electrical connection 208 fixing of solenoid valve alongwith pneumatic / electrical connection 209 replacement of actutor diapragm ( pneumatic ) of any size actuator 210 removal of piston / power cylinder alongwith pneumatic connection 211 fixing of piston / power cylinder alongwith pneumatic connection 212 lapping of plug , seat & other sealing surface of control valves 213 greasing of control valve parts 214 removal of air filter regulator set with fittings 215 fixingof air filter regulator set with fittings 216 jobs in bagging plant area 217 removal and cleaning of level probes & refixing 218 cleaning of machines, weigh pans, solenoid valves, power cylinders etc. 219 replacement of broken weigh pan assembly of bagging machines & repairing by doing necessary cutting / welding, cleaning etc. 220 cleaning of avery / tulaman pre determined weighing scales ( check weighers ) 221 cleaning of et 6 belt weighers framework and related equipments 222 assistance in calibration of bagging machines by putting weights 223 fixing of power cylinder of piston dia.upto 100mm on the machine 224 removing of power cylinder of piston dia.upto 100mm from machine 225 removal of solenoid valve spool type 5 ports 226 fixing of solenoid valve spool type 5 ports 227 laying / removing pvc / nylon tubing upto 12mm size 228 filling of oil in bagging machine air regulators 229 replacement of proximity sensor in pandoor / bagholder of bagging machines 230 replacement & repairing of broken feed gate assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 231 removing, cleaning & fixing of anti vibration pads in bagging machines 232 replacement & repairing of brokenbag holder assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 233 replacement of load cell ( including all accessories ) of urea bunker level measuring system / urea belt weigher / weigh bridges 234 other misc.jobs 235 removing of manual call points mcp ) including accessories 236 refixing of manual call points mcp ) including glanding and termination 237 removing of heat, flame or smoke detectors & termination 238 refixing of heat, flame or smoke detectors & termination 239 painting of control valves, actuators including accessories & other insts. with mounting stand 240 writing of tag nos. on instruments, control valves, etc 241 cleaning of instruments, control valves, local panels, ccr cabinets etc 242 laying of heat detector cable on cable trays & their connections 243 removing of heat detector cable on cable trays 244 removal of speed / vibration / axial displacement probe / extension cable 245 fixation of speed / vibration / axial displacement probe / extension cable 246 removal of field tachometer / speed indicator 247 fixation of field tachometer / speed indicator 248 control panel cutting ( for cable entry or providing new instrument ) 249 removal of low explosive limit detector / ammonia detector / co detector 250 fixation of low explosive limit detector / ammonia detector / co detector 251 transportation of instruments / materials from respective plant to instrument workshop / store 252 transportation of instruments / materials from instrument workshop / store to respective plants 253 removal of uv flame scanner & cleaning 254 fixation of uv flame scanner 255 removal of weephole probe in urea reactors 256 fixing of weephole probe in urea reactors 257 removal, cleaning / washing and fixing of suction air filters of ccr / lcr control cabinets ( dcs / esd / ops / his / vms & printer consoles ) 258 panel cooling fans removing, cleaning & checking 259 panel cooling fans fixing ( including mounting arrangement ) 260 to assist nfl employees in executing various instrument maintenance jobs in routine day to day maintenance 261 helper ( un skilled ) 262 instrumentation technician ( skilled ) 263 supply of contract labour for unplanned / unforeseen plant breakdown jobs & planned shutdown 264 instrumentation technician ( skilled ) 265 instrumentation fitter ( skilled ) 266 helper / mazdoor ( un skilled ) 267 rigger ( skilled ) 268 welder ( skilled ) 269 electrician ( skilled ) 270 note: party may fill any rate in soqr sl. no. 14 & 15 but not less than minimum amount as ilustreted in price bid format part b of nit. => limited...

Department of Financial Services - Madhya Pradesh

29560105 bids are invited for rifflingonce in a year fire extinguisher abc type 4 kg , smoke detector agni make qly amc 9 district of bpl do 2 zone , amoke detector qly amc 9 district of bpl do 4 zone total quantity : 1...

High Court - Madhya Pradesh

29498072 tender for annual maintenance contract for firefighting equipment and fire hydrant system 1. complete paint of hyder & raiser and branch lines and all require equipments with signal red (pipe dia includes and ⌀ 100 mm, ⌀ 80 mm, ⌀ 50 mm, ⌀ 40 mm, ⌀ 32mm & ⌀ 25 mm) qty in running ft. 2. smoke detector (qty. in nos.) 3. hydrant valve (qty. in nos.) 4. panel for fire pump 5. hose reel assy. 6. hose box (paint, glass & gasket) 7. two way inlet 8. fire alarm panel 9. battery 7ah 12 v 10. support stand for two way & hydrant 11. sprinklers...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

29165120 supply, installation, testing and commissioning of co2 fire suppression system including dismantling of old co2 system to protect generator at 2x15 mw bhps ii silpara. , seamless cylinders, ccoe approved capacity 45.0 kg complete in all respect if any existing cylinder failed in tests (on actual basis) , refilling of co2 gas with 99.9 % purity, each cylinder gas capacity 45.0 kg , co2 cylinder bank along with weighing device mounting rail (suitable for 08 nos. of 45.0 kg capacity co2 cylinders) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , slave valve with pneumatic actuator & manual lever , non return valve suitable for fixing at co2 discharge header, make: tpfps/equivalent , high pressure discharge hose , high pressure pneumatic actuation hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve , 32 nb co2 directional valve with pneumatic actuator & limit switch , 25 nb co2 directional valve with pneumatic actuator & limit switch , continuous gas weighting monitor led type , continuous gas weight monitor control panel suitable to connect 10 nos. of gas weight monitors common for all type of weight monitors , manifold safety valve , pressure switch , discharge warning display unit , inhibit/ abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working on 4 zones with 02 nos. spare zone , smoke detector/ probe type fixed temperature heat detector with junction box , high pressure discharge nozzle with bowl , hydro test of seamless cylinders , painting of the old co2 cylinders with two coat of post office enamel red paint over one coat of red oxide primer etc. complete in all respect , installation, testing & commissioning of the system...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

29165118 design, supply, erection, testing and commissioning of co2 fire suppression system for hydro generator protection at 2x10 mw bhps iv jhinna. , seamless cylinders, ccoe approved capacity 45.0 kg complete in all respect with gas and duly painted ( required if any co2 cylinder fails in h.p. tests , refilling of co2 gas with 99.9 % purity, each cylinder gas capacity 45.0 kg , hp test of cylinders , co2 cylinder bank along with weighing device mounting rail ( suitable for 08 nos. of 45.0 kg capacity co2 cylinders ) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , sleeve valve with pneumatic valve , non return valve suitable for fixing at co2 discharge header , high pressure discharge hose , high pressure interconnection hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve , 32 nb co2 directional valve for initial discharge , 25 nb co2 directional valve for delayed extended discharge , online continuous gas monitor led type , weight loss gas monitor control panel suitable to connect 20 nos. of gas weight monitors common for all type of weight monitors , manifold safety valve , discharge pressure switch , discharge warning display unit 24 v dc , inhibit / abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working 2 zones with battery backup , smoke detector / probe type fixed temperature heat detector with junction , high pressure discharge nozzle with bowl , installation, testing & commissioning of system , special tool kit required for maintenance and troubleshooting , seamless m.s. pipe of schedule grade with required forged fittings., m.s. support with bolts, u clamps etc. duly painted in red and fixing pipes. m.s. seamless astm 1 106, sch 40 , transportation charges include lodging and boarding...