Central Reserve Police Force - Madhya Pradesh

40817575 painting of sector hqr, range building, sos mess, electric sub station, cleaning of 05 nos sump, 03 nos oht and 993 nos. water storage tanks, repair of narmada water supply line various water supply pipelines and pipe work jawan barrack...

South Eastern Coalfields Limited - Madhya Pradesh

40729261 construction of 03 nos. retaining wall, 05 nos. plain cement concrete foundation for pump in 9d sump and md sump and 04 nos. platform for ug electrical sub station in johilla top seam and johilla bottom seam at pali ug mine, pali sub area of johilla area...

Northern Coalfields Limited - Madhya Pradesh

40729241 repairing of drain in periodical renewal sub station, erection of wall besides track line of silo iii, brick work sheet work and other miscellaneouscivil works in section ii and section iii of old chp at jayant periodical renewaloject repairing of drain in periodical renewal sub station, erection of wall besides track line of silo iii, brick work sheet work and other miscellaneous civil works in section ii and section iii of old chp at jayant periodical renewaloject...

Bharat Sanchar Nigam Limited - Madhya Pradesh

40534002 tender for comprehensive maintenance, upkeep and operation of electro mechanical services of te building and staff quarters at shivpuri under ba gwalior.; 2 comprehensive maintenance of following electromechnical services as per the asset details, specification and conditions attached and providing one semi skilled labour for upkeep, repair and operation in general shift only. ( a ) e.i. & fans. ( b ) compound lighting ( c ) pumps ( d ) sub station ( e ) e. a. sets ( f ) a.c. system ( g ) fire detection system ( h ) electrical appliances. 3 a ) labour component for upkeep, repair and operation of ems ( one semi skilled labour in general shift per month ) 4 b ) comprehensive maintenance of ems 5 sh ii: preventive maintenance and consumable items as and when required on measurable basis 6 servicing & routine maintenance ( b check ) of followingcapacity of dg set complete with cleaning of air cleaner element, replacement of engine lube oil of proper grade ( seal pack of reputed make ) , replacement of lube oil filter elements, replacement of fuel filter elements, retighten cylinder head nuts, adjust engine valve clearance, replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i / c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of dg set after servicing etc as directed. 7 i ) 125 kva dg sets 8 supply , installation, testing and commissioning of 12 volt, heavy duty , hybrid alloy plate, semi maintenance free , storage type, ready to usebattery set for existingdeasetincludingproper initial factory charging of unit, providing and fixing, terminal and thimbles ( if required ) , greasing the battery terminalscomplete as required.180 ah, 12 volt ( m / s exide fxpo xp180 or equivalent of approved make ) note 1 ) agency shall consider rebate for old battery while quoting of rates. additional requirement to be borned by agency without extra cost. 9 dehydration / filtration of oil of transformer, ht panel and potential transformer along with break down voltage testing before and after filtration, acidity testing after filtration, silica gel change complete as required.note1 ) breakdown voltage of oil after dehydration / filtration shall be minimum 60 kv rms.2 ) total acidity max after dehydration / filtration shall be 0.05 mg koh / gm.3 ) max water content after dehydration / filtration shall be 15 ppm. 10 sh iii: one time maintenance of ems asrequired on measurable basis as per instruction of engineer in charge ( for removal of initial defects in services ) 11 replacement of the following faulty / burnt electrical items / accessories in the existing substation and distribution system, suitable for operation on 3 phase, 33kv / 415v / 230v, 50hz, ac supply system including cleaning of installation and lt panels and distribution boards etc complete with interconnections, testing and commissioningas reqd at site. 12 630 amps. hrc fuse. 13 transformer oil. 14 acsr conductor jumper up to 3.0 mtrs. length. 15 gang operated air break switch in the existing 200 kva , 33 kv outdoor substation complete. 16 threephase lcd multifunction meter indicating v, a, f, pf, power, energy ( m / s l&tnova series, cat. no. wm30kfc3c00 or equivalent similar superior make with c.ts 17 led type indication lampswith suitable rating hrc fuses with base & carrier ( led ofm / s esbee l&t, elr&y240a 240v + elb240a 240v ac or equivalent similar superior make ) 18 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 19 100 amp rating, four pole, mccb with variable thermal magnetic release, ( release range 25 32, 50 63, 80 100a ) breaking capacity 25ka at 415v, 50hz, ac supply and conforms to is / iec 60947 2 ( make and model , m / s l&t dn0 100c or equivalent similar superior make ) with ( ics = 100% icu ) 20 repairing of the existing old and damaged foundation i / c white washing etc. complete as required. 21 painting of the existing ht poles ( 06 nos. ) i / c its cross arms / members etc. complete as required. 22 earthing with g. i. earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required. ( for neutral earthing of the existing transformer ) . 23 providing and fixing 25mmx5mm g. i. strip in 40 mm dia g. i. pipe from earth electrode i / c connection with g. i. nut, bolt, spring washer, excavation and re filling etc. as required. 24 providing and fixing 25mmx5mm g. i. strip on surface or in recess for connections etc. as required. 25 replacement of the following faulty / burnt / damaged electrical items / accessories suitable for operation on 230v / 415v, 50hz, single / three phase ac supply , in the existing electrical installation , fan and fittingsi / c supplying making interconnections, testing & commissioning etc. complete as required: 26 electronic choke for 36 / 40 watt fluorescent lamp . 27 30 watt led lamp with holder ( for campus light ) . 28 1200 mm ( nominal ) size, 40 watt fluorescent tube rod. 29 2.5 mfd condenser ( for ceiling fans ) . 30 9 watt led bulb with holder. 31 20 watt led lamp with holder ( for campus light ) . 32 1200 mm ( nominal ) size, 20 watt led tube rod 33 6 32 amps. single pole c curve mcb. 34 32 amps. triple pole and neutral mcb. 35 starter for 4feet, 40 watt fluorescent fitting. 36 5 / 6 amps piano type switch 37 15 / 16 amp piano type switch 38 3 pin 5 / 6 amp socket outlet 39 6 pin 15 / 16 amp socket outlet 40 supplying and fixing two module stepped type electronic fan regulator. 41 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required 42 1 x 1.5 sq. mm 43 2 x 4 sq. mm 44 supplying and laying 2x4 sqmm. al. pvc insulated and pvc sheathedunarmoured cable in the existing surface / recessed steel / pvc conduit as required 45 repairing / rewinding of the following faulty electrical items / accessories complete with connections, testing and commissioning etc. as reqd: 46 rewinding of 1200 / 1400 mm. sweep ceiling fan. 47 rewinding of 450 mm. sweep exhaust fan. 48 supply, installation, testing and commissioning of following rating and types of prewired fitting complete with all accessories driver and lamps etc., suitable for operation on 230 volts, 50 hz single phase ac supply i / c fixing the same directly on wall / celling including connection with 3x 1.5 sqmm frls pvc insulated copper conductor flexible cable etc as required. ( m / s. bajaj / havells / philips ) . 49 1200 mm ( nominal ) , 20 watts ( + / 2 watts ) energy efficient linear box led batten light having 6500k colour temp., minimum 1900 lumens, 95 lumen / watt efficacy and 0.9 power factor . 50 replacement of the old, life expired fittings with the following rating and type fitting suitable for operation on 230volts, 50 hz, single phase, ac supplyi / c installation the same on the existing bracket on the wall / pole, making interconnections, testing, commissioning etc as reqd at site . ( preferred makes syska / wipro / havells / crompton / bajaj / osram or similar superior make ) . 51 led street light luminaire of nominal wattage 30w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 52 led street light luminaire of nominal wattage 60w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 53 providing and fixing of 300 mm sweep, 1400 rpm domestic exhaust fan suitable for operation on 1 phase, 50 hertz, 220 230 volt ac supplyin existing opening as reqd. ( crompton, bajaj, havells, almonard or s.s.make ) 54 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cm / m / w ) minimum 6.00, air delivery minimum 210 cum / min , 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 55 sh iii: pumps & lt panels 56 sitc of dol motor starter with overload protection and single phase preventor , suitable for operation upto 7.5 hp, 415 volts, 50hz, three phase, monoblock pump set having suitable rating contactor, relay, voltmeter, ampere meter, on / off push button assembly, indicators, connection plate, etc. complete as required. ( m / s. l&t mu c6 dol starter, bch or similar superior make ) . 57 supplying and fixing of 3ph led ammeter accuracy class 1.0 and suitable rating cts complete as required 58 supplying and fixing of 3ph led ammeter accuracy class 1.0. complete as required. 59 sh iv: sac & pac units 60 servicing of existing one no 7 tr capacity high precision air conditioner unit with necessary dismantling of covers wherever required, pressurized wet servicing of evaporator and condenser coil, cleaning of oil stains if any, cleaning of evaporator filters with water , checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring for satisfactory operation of package ac unit, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 61 supplying and top up charging of fresh refrigerant r 22 / m 22 / c 407in the existing window ac / split ac / package ac units unitcomplete as per manufacturer / departmental specifications, etc as required at site.in the pac no.1 & sac 62 carrying out wet servicing of existing one nowindow / split type ac units upto 2.0tr capacitycomplete with completecleaning and washing of indoor and outdoor units , cleaning of filter, checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring , providing necessary tape and thimbles, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 63 supplying and fixing / replacement of following electricalitems, suitable for operation on 230v / 415 v , single phase / three phase , 50hz , ac supply in the existing faulty window ac / split ac units / package ac unitcomplete with installation, making interconnections, testing and commissioning etc.as required at site. ( 1.5 tr window, 1.5 / 2 tr split ac and 3 tr hshf ) ( note: the faulty material / compressorshall be handed over to the agency . the agency shall consider suitable buyback pricewhile quoting for the item ) a ) supplying and fixing ofrunning capacitor 50 mfd 64 repairing of the following faulty components ofexisting split / window type ac units including dismantling , repairing , replacement , reinstallation and labour charges complete in all respect for the same, making interconnection, testing and commissioning etc as reqd at site. 65 rewinding of condenser fan motor of 1.5 / 2 tr split ac 66 sh v: fire detection system & fire extinguishers 67 repairing offollowing zone , existing fire detection control panel i / c cleaning , repairing of zonal cards, mother board, control card, charging system, replacement of the faulty / burnt diodes, integrated circuits, leds and power supply unit etc. complete with testing as required. 68 10 zones main control panel. 69 4 zones local control panel. 70 6 zones local control panel. 71 supplying, installation, testing & commissioning of following type fire detectors and other accessories in the existing fire detection and alarm system completewith all connections etc. as required. 72 smoke detector with built in led and mounting base complete. 73 dual chamber heat detector ( heat cum rate of rise in temperature type ) . 74 responseindicator on surface / recess ms box having two leds and metallic cover complete.. 75 manual call point ( pill box ) of ms construction with stainless steel chain and hammer assembly. 76 fire alarm sounder with facility to make announcement mounted in ms box ( 16 swg ) with hinged cover plate. 77 cleaning of the entire existing detectors installed in the bldg. i / c testing etc. complete as required. 78 refilling / recharging of the following type / capacity fire extinguishers as per bis 2190:2010 specifications including repair of fire extinguishers and replacement of defective spare parts like nozzle, safety clip, horn, water, rings, washer, plunger etc. as required and collection, transportation and delivery charges from various exchanges to refilling station and vice versa etc. complete as required: 79 4.5 kg. portable co2 type fire extinguisher....

Central Public Works Department - Madhya Pradesh

40436852 annual repair maintenance of electrical installations sub station, dg set, ff, fa and lift, vrv vrf system at agmp audit office bldg. gwalior during 2023 24 sh : annual comprehensive maintenance of vrv vrf ac system of lg make....

Power Grid Corporation Of India Limited - Madhya Pradesh

40334813 no. i tender for pre bid tie up for 765kv sub station ss 19t for a. establishment of 2x1500 mva, 765/400 kv and 2x500 mva, 400/220 kv icts at ishanagar (new) including 1x125 mvar, 420kv bus reactor b. lilo of one circuit of jabalpur orai 765 kv d/c line at ishanagar 765 kv s/s (new).associated with “western region expansion scheme xxxiii (wresxxxiii): part c” through tariff based competitive bidding (tbcb) route prior to rfp bid submission by powergrid to bpc....

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

40256709 supply, installation, testing and commissioning of new 11 kv line for bifurcation & interconnection, additional 11 kv bay at 33 / 11 kv sub station, augmentation of conductor of 11 kv lines, additional distribution transformer substations with associate new 11 kv lines, lt line on ab cable, conversion of bare lt line with ab cable, augmentation of lt ab cable, 11 kv line crossing agriculture & non agriculture feeder, other associated work and supporting works such as dps, tps, crossing etc. package vi b [ lot xi ( b ii ) bhind circle ] in mehgaon division, gwalior region of mpmkvvcl, bhopal under revamped reforms based and results linked distribution sector scheme...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

40256678 supply, installation, testing and commissioning of new 11 kv line for bifurcation & interconnection, additional 11 kv bay at 33 / 11 kv sub station, augmentation of conductor of 11 kv lines, additional distribution transformer substations with associate new 11 kv lines, lt line on ab cable, conversion of bare lt line with ab cable, augmentation of lt ab cable, 11 kv line crossing agriculture & non agriculture feeder, other associated work and supporting works such as dps, tps, crossing etc. package vi b [ lot xi ( b i ) ] gohad division of bhind circle, gwalior region of mpmkvvcl, bhopal under revamped reforms based and results linked distribution sector scheme ( rdss ) ...

Central Public Works Department - Madhya Pradesh

40195652 maintenance of electronic installation & fans i / c street lighting repair maintenance of p / sets, rmo dg set, sub station & acs at nirman sadan, cgo building, bhopal. ( sh: amc of acs ) ...

Urban Administration & Development Department - Madhya Pradesh

40116034 construction of cc drain at ward 3 rajendra sahu se nemsingh ke ghar tak, cons of talab ghat nirman at ward 15 , cons of cc road at wrd 5 main road to lilabai house tak, cons of cc road at wrd 4 sector c to pathak house tak, cons of shopping complex at ward 11, cons of community hall at ward 14 bangavan, cons of cc road at ward 8 mannu to vikesh house, cons.of cc drain at ward 5 anganbadi kendra to bada naala, cons of cc drain at ward 6 mithailal house to triveni khatal, cons of cc drain at ward 7 main road to avinash house, cons of cc drain at ward 7 kushwaha brother to main naala, cons of pavor block & drain wrd 7 rajaram to sub station main road, cons of bridge at wrd 2 near abhy shah house to puliya tak, cons of cc road at ward 9 chp road rammilan vishwkarma , cons of cc road at wrd 13 gudiya baiga to shiv mandir road, cons of cc drain at wrd 9 koshal yadav to guddu prajapati house, cons of bridge & cc approach at wrd 12, cons of cc drain at wrd 10 joginderto kanhaiya house, cons of rcc slab culvert at ward no.06 main road...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

40027166 tender for supply, installation, testing and commissioning of new 11 kv line for bifurcation & interconnection, additional 11 kv bay at 33/11 kv sub station augmentation of conductor af 11 kv lines, additional distribution transformer substations with associate new 11 kv lines, lt line on ab cable, conversion of bare lt line with ab cable, augmentation of lt ab cable, 11 kv line crossing agriculture & non agriculture feeder other associated work and supporting works such as dps, tps, crossing etc. package vi b (l xi b(18) in gohad division & mehgaon division of bhind circle) gwalior region of mpmkvvcl bhopal under revamped reforms based and results linked distribution sector scheme (rdss)...

Uttar Pradesh Rajkiya Nirman Nigam Limited - Madhya Pradesh

39965694 erection ( work contract ) items for thdc works singrauli ( m.p. ) 2 h beam 13 meter 152 x 152 mm 37.1 kg / meter 3 33 kv v cross arm 1.5 mtr ( 5ft ) centre made from 75x75x6mm angle 4 back clamp for h beam pole of 65x8mm ms flat 5 33 kv top clamps 75x75x6mm angle type 6 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 7 33 kv, 10 kn pin composite polymer insulator 8 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 9 jointing sleeves ( aluminium ) for dog conductor 10 stay set 20 mm complete 11 h.beam clamps 65x8mm flat 12 concreting ( 1:3:6 ) of h beam @ 0.65 cmt.per pole ( base pedding + muffing ) 13 concreting ( 1:3:6 ) of stay @ 0.3 cmt. per stay ( 20mm ) 14 red oxide paint 15 aluminum paint 16 anti climbing device ( barbed wire 3.5 kg ) gs 2.5 mm dia ( 12 swg ) 17 danger board enameled 33 kv 18 dc.cross arms 8` ( 2.4 meter ) centre to centre 100x50x6 mm channel 19 33 kv , 45 kn disc polymer long rod type t&c insulator 20 bracing set for 8 feet ( 2.45 mtr ) centre dp angle 21 bracing set for 5 feet ( 1.5 mtr ) centre dp angle 22 33 kv suspension clamps with attachment for a.b cable 23 33 kv tension clamps ( dead end ) with attachment for a.b cable 24 33 kv arial bunch cable 95 sqmm 25 cable straight through joint kits suitable for 95 sq.mm. 26 cable end termination kits suitable for 95 sqmm 27 xlpe cable 33 kv armoured 3x300 sqmm 28 outdoor / indoor end termination kit ( 3x300 sqmm for 2 way rmu ) 29 33 kv bridling cross arms 75x75x6mm 30 33 kv guarding channel 75x40x6 mm 31 fixing of 25 mtr high mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 4 mm. top dia minium 150 mm, bottom dia 460 mm base plate 32 mm thick suitable for wind velocity as per is 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 14 luminaries & its control gear boxes 1.5 hp power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing / site reuiment along with 08 nos foundation bolts nuts, washers, anchor plates etc complete in all respect ( including erection cost ) . 32 itc of outdoor type feeder pillar ( powder coated metal sheet outer door thickness 2mm, inner door thicness 1.6 mm, each door shall be provided with 2 numbers industrial locks ) , for service connection in underground lt line incoming al. ec grade bus bar for lilo 300 amp. 30x10 mm. mccb: 1 no. 125 amp, 18 ka b.c at 415 volts tp mccb with copper neutral link, busbar:1 set 200 amp , aluminium busbar, outgoing mccb current rating: 32 amp, 10 ka b.c., , 30 nos. spn . is 5039, is 13947, iec 65029, is 2147 and relevant is standards 33 fixing of 350 watt flood light ( long range ) 34 fixing of 350 watt flood light ( wide spread ) 35 fixing of 4c x 25 sqmm aluminium armoured cable xlpe insulated 36 laying of one number armoured / unarmoured power cable 1.1kv grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil / murrum / soft rock, sand cushioning, protective covering and refilling the pit etc. as required 37 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1kv grade as required. ( 4c x 25 sqmm ) 28 mm 38 fixing of mccb 100 amp ( 4 pole ) with frame complete 39 fixing of 5 core x 6 sq.mm trailing copper cable 40 fixing of xlpe insulated frls heavy duty power cable conforming is 7098 ( part 1 ) 1988, 1100 volt grade, 4 core 2.5 sq. mm isi marked with copper stranded / solid conductor. 41 fixing of xlpe insulated frls heavy duty power cable conforming is 7098 ( part 1 ) 1988, 1100 volt grade, 2 core 2.5 sq. mm core isi marked with copper stranded / solid conductor. 42 earthing with g.i. earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mt. long etc with charcoal / coke and salt as required. 43 sub station installation, testing & commissioning of out door type 10 mva power transformer oftc with on load tap changer is 2026, iec296, and any other relevant is including loading, unloading, local carriage & erection of the same on plinth & making all necessary connection etc. complete in all respects as per specification. cable termination box with disconnecting facility for 33 kv xlpe cable at 33 kv side. cable termination box with disconnecting facility for 11 kv xlpe cable at 11 kv side. on load tap changer+ / 7.5@2.5%, bi directional roller, conservator with drain valve, earthing ferminals, double diaphragm explosion vent, radiator with top & bottom shut off valve, first filling of oil including make up fill, silica gel breather with oil seal, rating and diagram plate, air release plug, buchholz relay with shut off valve, winding temperature indicator ( wti ) , oil temperature indicator ( oti ) , megenatic oil level guage, pressure relief device, marshalling box. no load losses 8kw, load losses 50kw, toleronce as per i.s. code 44 installation, testing & commissioning of 33kv vcb panel 1250amp , copper bus bar , inbuild c.t & p.t, protection relays , digital instruments like ameter , voltmeter etc. incomer 02nos bus coupler 01 no outgoing 02 nos 45 installation, testing & commissioning of 11kv vcb panel 1250amp , copper bus bar , inbuild c.t & p.t, protection relays , digital instruments like ameter , voltmeter etc. incomer 02nos bus coupler 01 no outgoing 08 nos 46 laying of one number xlpe power cable of 33 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 47 upto 120 sq. mm 48 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 33 kv grade as required: 49 120 sq. mm 50 supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 33 kv grade as required: 51 120 sq. mm 52 laying of one number pvc insulated and pvc sheathed i xlpe power cable of 11 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refillinq the trench etc as required. 53 above 120 sq. mm and upto 400 sq. mm 54 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required: 55 300 sq. mm 56 supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required: 57 300 sq. mm 58 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1 :2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refillinq etc as required. 59 300 mm dia 60 laying of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc 61 50 sq. mm 3 1 / 2 core 62 150 sq. mm 3 1 / 2 core 63 supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of pvc insulated and pvc sheathed i xlpe aluminium conductor cable of 1.1 kv grade as required. 64 31 / 2x50sq. mm 65 31 / 2x150sq. mm 66 erection, testing and commissioning of 48 v dc, 200 ah, vrla battery consisting 24 no cell of 2 volt each. including battery charging arrangement with all ac / dc ameter and voltmeter meters. 67 erection, testing and commissioning of direct curent distribution board ( dcdb ) 24 volts indoor floor / wall mounted comprising of 1 no. 2p / 100a dc mccb 5a switch fuse unit as incommer and 8 no. 2p / 40a mccb 5a switch fuse units for each individual outgoing circuit of indoor control panels, indoor / outdoor vcb panels, 1 no. 2p / 40a mccb 5a switch for control room emergency dc lighting including 20% as spare. each incoming & outgoing shall have indicating lamp, 68 erection, testing and commissioning of acdb 415 v, along with three phase neutral voltmeter, three phase ammeter and selector switches, 1no. 200 amps tpn switch fuse unit as incomer, 1no. 63 amp. tpn mccb switches as outgoing feeders & 2no. 32 amp. mccb as outgoing for yard and control room lightining and 6 no. 16 no. mccb for control panels, each incoming & outgoing shall have indicating lamp. including 20% spare 69 installation, testing & commissioning of lattice structure 70 fixing of 33 kv, isolator 800 amp. ( turn and twist type ) 71 equipments installation, testing & commissioning of bis certified energy efficiency level iii ( old ) / level ii ( new ) convential 11 / 0.433kv, 100 kva distribution transformer 72 installation, testing & commissioning of marshelling box with 10 no. connectors 73 erection, testing and commissioning of lt distribution box with 1.2 mm thick ms powder coated sheet, 200 a mcb on incoming & 6 no. 125 a hrc fuse base including 100 a hrc fuse , for 100 kva transformer made of smc 74 fixing of transformer mounting channel ( 100x50x6mm ) 75 fixing of copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 76 fixing of copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 77 fixing of copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 78 fixing of copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 79 fixing of bi metallic clamp for power transformer of brass flat 50x50x10mm 80 for gantry structure ( 33kv ) installation, testing & commissioning of h beams 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long = 482.3 kgx 81 installation, testing & commissioning of d.c. channel 4.8 mtr. centre 100x50x6mm for 33kv gantry structure ( each weight 99.90 kg ) 82 installation, testing & commissioning of back clamp suitable for h beam ( ms flat 65x8 mm ) each weight 1.92 kg 83 installation, testing & commissioning of 33 kv top clamps 75x75x6 mm angle ( each weight 3.58 kg ) 84 installation, testing & commissioning of earthing coil ( coil of 115 turns of 50 mm.dia. and 2.5 mtrs. lead of 4.0 mm. g.i wire ) 85 installation, testing & commissioning of aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 86 suppy and erection of single piece nonlinear resistor type lightning arrestor suitable for3wire 33kv overhead lines with rated voltage 30kv ( rms ) with a nominal discharge current rating of 10ka ( station class ) and complete with galvanized clamping arrangement , g.i bolts , nuts, washers etc. as required. 87 suppy and erection of 33kv pin insulator complete with large steel head g.i. pin , nuts, washers etc as required. 88 stone block / pre cast block for base pedding 450x450x75 mm 89 concreting ( 1:3:6 ) 0.36 cmt for [ h beam 7 m, 9 m & rsj 9.3 m, pcc pole dp / tp / 4p / 6p of 140 kg. 8 m 200 kg. 9 m 280 kg. 9 m ] , 0.56 cmt for 11 m, 0.60 cmt for 13 m, 0.67 cmt for 15 m per pole including muffing with pole pit digging by hydra m / c. 90 clamp suitable for 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long h beam ( each weight 3.2 kg ) 91 11kv outgoing lines ( 06 nos bays ) installation, testing & commissioning of 200 kg., 9.0 mtrs. long pcc poles 92 installation, testing & commissioning of d.c. channel 4.8 mtr centre 100x50x6mm for 11kv ( each weight 99.90 kg ) 93 installation, testing & commissioning of back clamp suitable for 280 kg pcc pole ( ms flat 65x8 mm ) each wt 1.92 kg 94 installation, testing & commissioning of 11 kv top clamps angle type 65x65x6 mm 95 suppy and erection of three piece nonlinear resistor type lightning arrestor suitable for 3wire 11kv overhead lines with rated voltage 9kv ( rms ) with a nominal discharge current rating of 5ka ( station class ) and complete with galvanized clamping arrangement , g.i bolts , nuts, washers etc. as required. 96 suppy and erection of 11kv pin insulator complete with large steel head g.i. pin , nuts, washers etc as required. 97 installation, testing & commissioning of mesh earthing for new 33 / 11kv sub station inblack cotton soil as per schedule g 3.1 98 installation, testing & commissioning 1500 kvar auto switch, 11 kv capacitor bank complete with individual fuses , interconnection , mounting racks, external fuses, mounting arrangement, bas insulator and accessories with earthing and marshelling box 99 installation, testing & commissioning of earthing of capacitor bank as per schedule g 6.1 ( for black cotton soil ) 100 installation, testing & commissioning of earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mt. long etc with charcoal / coke and salt as required. 101 laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. 102 miscellaneous items ( i ) safety helmets 103 ( ii ) tong tester digital ( 1000a, 500v ) with associates accessory 104 ( iii ) chain pully block 3ton with 15 metre chain. 105 ( iv ) wall mounting type holder for hydrometer 106 megger anolog 1000 v 107 megger anolog 5000 v. 108 ( vii ) battery hydrometer 109 ( viii ) rubber hand gloves for 15kv ( seamless ) 110 ( ix ) transformer oil dielectric breakdown test kit 111 fixing of fire bucket, round bottom made of g.i. sheet 9 11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of engineer in charge. 112 fixing of shock treatment chart ( prescribed under i.e. rules ) duly framed with glass and supported from back with hard board or soft board with supply of all material labour t&p for proper completion of work 113 fixing of fire extinguisher, abc type 9.00 kg. capacity ( isi marked is : 15683 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 114 fixing of c02 type fire extinguisher 6.5 kg. capacity ( isi marked is : 2878 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 115 laying of 11kv 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. 116 earth resistance tester ( 20 / 200 / 2000ohms ) digital 117 filter machine 250gph ( transformer oil filtration purpose ) 118 fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrc fuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect. auto / mannual selector switch 24 hour programmable timer. 40a tpn 119 fixing of mccb ) suitable for 3 phase & n, 4 pole, ac supply with micro processor release ( mccb, 25ka, 40 & 100 amps, 4p ) 120 fixing of steel enclosure, neutral bar suitable for mcb / rcbos / mccb ( 63a / 100a, 3p / 4p enclosure ) 121 laying of 4 x 10sq.mm aluminium cable a2xfy type. 122 cables & wirings wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface i recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required 123 group c 124 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface i recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc .as required. 125 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 126 wiring for light / power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 127 wiring for circuiv submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 128 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 129 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 130 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 131 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 132 4 x 10 sq. mm+ 2 x 6 sq. mm earth wire 133 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 134 2 pair 135 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required 136 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 137 20 mm 138 25 mm 139 40 mm 140 supplying and fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 141 75 mm x 75 mm x 60 mm deep 142 100mmx100 mm x 60 mm deep 143 150 mm x 75 mm x 60 mm deep 144 150mmx150 mm x 60 mm deep 145 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 146 5 / 6 a switch 147 2 way 5 / 6 a switch 148 15 / 16 a switch 149 3 pin 5 / 6 a socket outlet 150 6 pin 15 / 16 a socket outlet 151 telephone socket outlet 152 tv antenna socket outlet 153 bell push 154 supplying, erection and testing of approved make electric ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, aluminium blades, without regulator, a.c. 230 250 volts including connections with all necessary material complete of approved as required confirming to is :374 / 2019 with upto date amendments. ( 1400 mm sweep ) 155 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 156 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 157 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 158 numbering of ceiling fan / exhaust fan / fluorescent fittings as required. 159 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 160 upto 450 mm sweep 161 supplying and drawing of utp 4 pair cat 6 lan cable in the existing surface / recessed steel / pvc conduit as required 162 2 run of cable 163 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / lsolator ) 164 6 way ( 4 + 18 ) , double door 165 8 way ( 4 + 24 ) , double door 166 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioninq etc. as required 167 single pole 168 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 169 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioninq etc. as required. 170 63a 171 100a 172 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 173 supplying and installing following size of perforated painted with powder coating m.s. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as required. 174 150 mm width x 50 mm depth x 1.6 mm thickness 175 200 mm width x 50 mm depth x 1.6 mm thickness 176 supplying and installing following size of perforated painted with powder coating m.s. cable trays bends with perforation not more than 17.5%, , joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as reauired. 177 150 mm width x 50 mm depth x 1.6 mm thickness 178 200 mm width x 50 mm depth x 1.6 mm thickness 179 supplying and installing following size of perforated painted with powder coating m.s. cable trays tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspenders etc as reauired 180 150 mm width x 50 mm depth x 1.6 mm thickness 181 225 mm width x 50 mm depth x 1.6 mm thickness 182 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. 183 fixing of 7 mtr gi octagonal pole of approved make ( top dia 70mm, bottom dia 130mm and base plate 12mm thik ) having 3mm thikness with single arm bracket ( 1 mtr length ) on rcc foundation including the cost of foundation, foundation bolts, excavation & back filling and required t&p completee in all respect 184 fixing of led street light fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 watt. confirming to ip 66 protection complete in all respects cat aaa 185 surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. all kinds of soil 186 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan ) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by engineer in charge. all kinds of soil 187 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 188 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete 189 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level :1:4:8 ( 1 cement : 4 coarse sand ( zone iii ) : 8 graded stone aggregate 40 mm nominal size ) 190 diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) :treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor: with chlorpyriphos / lindane e.c. 20% with 1% concentration 191 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) . & centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform 192 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) . & centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform 193 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) . & centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform 194 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level : 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) 195 reinforced cement concrete work in walls ( any thickness ) , including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 ( 1 cement : 1.5 coarse sand ( zone iii ) : 3 graded stone aggregate 20 mm nominal size ) 196 centering and shuttering including strutting, propping etc. and removal of form for :lintels, beams, plinth beams, girders, bressumers and cantilevers 197 centering and shuttering including strutting, propping etc. and removal of form for :suspended floors, roofs, landings, balconies and access platform 198 centering and shuttering including strutting, propping etc. and removal of form for :foundations, footings, bases of columns, etc. for mass concrete 199 centering and shuttering including strutting, propping etc. and removal of form for :columns, pillars, piers, butments, posts and struts 200 brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:cement mortar 1:6 ( 1 cement : 6 coarse sand ) . 201 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) 202 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in cement mortar 1:4 ( 1 cement : 4 coarse sand ) 203 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 204 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including isi marked stainless steel butt hinges with necessary screws 205 providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size 206 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete.fixed to steel windows by welding 207 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 208 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) . 209 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. mild steel and medium tensile steel bars 210 fixing of steel or wooden chaukhats in position. 211 ( a ) door chaukhats 212 ( b ) window chaukhats 213 ( b ) ventilator chaukhats 214 15 mm cement plaster on plinth side of single or half brick wall of mix : 1:4 ( 1 cement: 4 coarse sand ) 215 12 mm cement plaster of mix :1:6 ( 1 cement: 6 coarse sand ) 216 15 mm cement plaster on rough side of single or half brick wall of mix : ( 1 cement: 6 coarse sand ) 217 forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness ( not less than 2 mm ) , nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the engineer in charge. 218 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 219 cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate 220 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600 mm 221 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600 mm 222 finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications :painting steel work with deluxe multi surface paint to give an even shade. two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @ 0.80 ltr / 10 sqm of approved brand and manufacture 223 finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications :painting wood work with deluxe multi surface paint of required shade. two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @0.75 ltr / 10 sqm of approved brand and manufacture 224 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade : new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 225 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work ( two or more coats ) over and including water thinnable priming coat with cement primer 226 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work ( two or more coats ) over and including water thinnable priming coat with cement primer 227 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 228 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 229 providing and fixing aluminium sliding door bolts, isi marked anodised anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm 230 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm 231 providing and fixing aluminium handles, isimarked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screw setc. complete :100 mm 232 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: ( a ) applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. ( b ) laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 233 ( c ) after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge. ( d ) finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 234 ( e ) the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : with average thickness of 120 mm and minimum thickness at khurra as 65 mm. 235 providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing epdm gasket, perforated aluminium spacers, desiccants, sealant ( both primary and secondary sealant ) etc. as per specifications, drawings and direction of engineer in charge complete. 236 supplying and fixing rolling shutters of approved make, made of required size m.s. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to is: 4454 part 1 and m.s. top cover of required thickness for rolling shutters.80x1.25 mm m.s. laths with 1.25 mm thick top cover 237 providing and fixing ball bearing for rolling shutters. 238 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes.110 mm diameter 239 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend 240 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 110 mm...

Uttar Pradesh Rajkiya Nirman Nigam Limited - Madhya Pradesh

39965574 supply of electrical items for thdc works singrauli h beam 13 meter 152 x 152 mm 37.1 kg / meter 2 33 kv v cross arm 1.5 mtr ( 5ft ) centre made from 75x75x6mm angle 3 back clamp for h beam pole of 65x8mm ms flat 4 33 kv top clamps 75x75x6mm angle type 5 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 6 33 kv, 10 kn pin composite polymer insulator 7 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 8 jointing sleeves ( aluminium ) for dog conductor 9 stay set 20 mm complete 10 h.beam clamps 65x8mm flat 11 stay gi wire 7 / 4.00 mm. ( 7 / 8swg ) 12 back filling of poles with boulders 13 concreting ( 1:3:6 ) of h beam @ 0.65 cmt.per pole ( base pedding + muffing ) 14 concreting ( 1:3:6 ) of stay @ 0.3 cmt. per stay ( 20mm ) 15 red oxide paint 16 aluminum paint 17 anti climbing device ( barbed wire 3.5 kg ) gs 2.5 mm dia ( 12 swg ) 18 danger board enameled 33 kv 19 aluminium binding wire and tape 20 ms bolt with nut 16x250 mm 21 dc.cross arms 8` ( 2.4 meter ) centre to centre 100x50x6 mm channel 22 33 kv , 45 kn disc polymer long rod type t&c insulator 23 33 kv strain hardware ( t&c type ) fittings 24 bracing set for 8 feet ( 2.45 mtr ) centre dp angle 25 m s bolt with nut 16x200 mm 26 m s bolt with nut 16x165 mm 27 m s bolt with nut 16x90 mm 28 m s bolt with nut 16x40 mm 29 bracing set for 5 feet ( 1.5 mtr ) centre dp angle 30 m s bolt with nut 16x140 mm 31 h.beam clamps 65x8mm flat 32 33 kv suspension clamps with attachment for a.b cable 33 33 kv tension clamps ( dead end ) with attachment for a.b cable 34 33 kv arial bunch cable 95 sqmm 35 cable straight through joint kits suitable for 95 sq.mm. 36 cable end termination kits suitable for 95 sqmm 37 xlpe cable 33 kv armoured 3x300 sqmm 38 outdoor / indoor end termination kit ( 3x300 sqmm for 2 way rmu ) 39 ms bolt with nut 12x140 mm 40 33 kv bridling cross arms 75x75x6mm 41 back clamp for h beam pole of 75x75x6 mm ms flat 42 33 kv top clamps bridling type 75x75x6 mm 43 33 kv guarding channel 75x40x6 mm 44 g.i. wires 5.0 mm. ( 6 swg ) 45 g.i. wires 4.0 mm. ( 8 swg ) 46 stay eye bolt 20 mm dia 47 supply of 25 mtr high mast shaft of approved make with rising system hot dip glavanized inside & out side dip, heaving pole sheet thickness 4 mm. top dia minium 150 mm, bottom dia 460 mm base plate 32 mm thick suitable for wind velocity as per is 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 14 luminaries & its control gear boxes 1.5 hp power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing / site reuiment along with 08 nos foundation bolts nuts, washers, anchor plates etc complete in all respect ( including erection cost ) . 48 supply of outdoor type feeder pillar ( powder coated metal sheet outer door thickness 2mm, inner door thicness 1.6 mm, each door shall be provided with 2 numbers industrial locks ) , for service connection in underground lt line incoming al. ec grade bus bar for lilo 300 amp. 30x10 mm. mccb: 1 no. 125 amp, 18 ka b.c at 415 volts tp mccb with copper neutral link, busbar:1 set 200 amp , aluminium busbar, outgoing mccb current rating: 32 amp, 10 ka b.c., , 30 nos. spn .is 5039, is 13947, iec 65029, is 2147 and relevant is standards 49 supply of 350 watt flood light ( long range ) 50 supply of 350 watt flood light ( wide spread ) 51 supply of 4c x 25 sqmm aluminium armoured cable xlpe insulated 52 supply of mccb 100 amp ( 4 pole ) with frame complete 53 supply of 5 core x 6 sq.mm trailing copper cable 54 supply of xlpe insulated frls heavy duty power cable conforming is 7098 ( part 1 ) 1988, 1100 volt grade, 4 core 2.5 sq. mm isi marked with copper stranded / solid conductor. 55 supply of xlpe insulated frls heavy duty power cable conforming is 7098 ( part 1 ) 1988, 1100 volt grade, 2 core 2.5 sq. mm core isi marked with copper stranded / solid conductor. 56 sub station supply of out door type 10 mva power transformer oftc with on load tap changer is 2026, iec296, and any other relevant is including loading, unloading, local carriage & erection of the same on plinth & making all necessary connection etc. complete in all respects as per specification. cable termination box with disconnecting facility for 33 kv xlpe cable at 33 kv side. cable termination box with disconnecting facility for 11 kv xlpe cable at 11 kv side.on load tap changer+ / 7.5@2.5%, bi directional roller, conservator with drain valve, earthing ferminals, double diaphragm explosion vent, radiator with top & bottom shut off valve, first filling of oil including make up fill, silica gel breather with oil seal, rating and diagram plate, air release plug, buchholz relay with shut off valve, winding temperature indicator ( wti ) , oil temperature indicator ( oti ) , megenatic oil level guage, pressure relief device, marshalling box. no load losses 8kw, load losses 50kw, toleronce as per i.s. code 57 supply of 33kv vcb panel 1250amp , copper bus bar , inbuild c.t & p.t, protection relays , digital instruments like ameter , voltmeter etc. incomer 02nos bus coupler 01 no outgoing 02 nos 58 supply, of 11kv vcb panel 1250amp , copper bus bar , inbuild c.t & p.t, protection relays , digital instruments like ameter , voltmeter etc. incomer 02nos bus coupler 01 no outgoing 08 nos 59 supply of 33 kv, 3c x 120 sq.mm. aluminium conductorxlpe pvc armoured cable including laying of one no. pvc insulated and pvc / xlpe power cable of 33kv grade of 120 sqmm in the masonry open duct as required 60 supply of 11 kv, 3c x 300 sq.mm. alluminium conductorxlpe pvc armoured cable including laying of one no. pvc insulated and pvc / xlpe power cable of 11kv grade of 300sqmm in the masonry open duct as required 61 supply of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc 62 50 sq. mm 3 1 / 2 core 63 150 sq. mm 3 1 / 2 core 64 supply of 48 v dc, 200 ah, vrla battery consisting 24 no cell of 2 volt each.including battery charging arrangement with all ac / dc ameterandvoltmeter meters. 65 supply of direct curent distribution board ( dcdb ) 24 volts indoor floor / wallmounted comprising of 1 no. 2p / 100a dc mccb 5a switch fuse unit as incommer and 8 no. 2p / 40a mccb 5a switch fuse units for each individual outgoing circuit of indoor control panels, indoor / outdoor vcb panels, 1 no. 2p / 40a mccb 5a switch forcontrol room emergency dc lighting including 20% as spare. each incoming & outgoing shall have indicating lamp, 66 supply of acdb 415 v, along withthree phase neutral voltmeter, three phase ammeter andselector switches, 1no.200 amps tpn switch fuse unit as incomer, 1no. 63 amp.tpn mccb switches as outgoing feeders & 2no. 32 amp. mccb as outgoingfor yard and control room lightining and 6 no. 16 no. mccb for control panels, each incoming & outgoing shall have indicating lamp. including 20% spare 67 supplyof lattice structure 68 supply of 33 kv, isolator800 amp. ( turn and twist type ) 69 equipments supply of bis certified energy efficiency level iii ( old ) / level ii ( new ) convential 11 / 0.433kv, 100 kva distribution transformer 70 supply of marshelling box with 10 no. connectors 71 supply lt distribution box with 1.2 mm thick ms powder coated sheet, 200 a mcb on incoming & 6 no. 125 a hrc fuse base including 100 a hrc fuse , for 100 kva transformer made of smc 72 supply of transformer mounting channel ( 100x50x6mm ) 73 supply, of copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 74 supply, of copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 75 supply, of copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 76 supply, of copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 77 supply, of bi metallic clamp for power transformer of brass flat 50x50x10mm 78 for gantry structure ( 33kv ) supply, of h beams 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long= 482.3 kgx 79 supply, of d.c. channel4.8 mtr.centre100x50x6mmfor33kvgantry structure ( eachweight 99.90 kg ) 80 supply, of back clamp suitable for h beam ( ms flat 65x8 mm ) each weight 1.92 kg 81 supply, of 33 kv top clamps 75x75x6 mm angle ( each weight 3.58 kg ) 82 supply, of earthing coil ( coil of 115 turns of 50 mm.dia. and 2.5 mtrs. lead of 4.0 mm. g.i wire ) 83 supply, of aaacdog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 84 stone block / pre cast block for base pedding 450x450x75 mm 85 concreting ( 1:3:6 ) 0.36 cmt for [ h beam 7 m, 9 m & rsj 9.3 m, pcc pole dp / tp / 4p / 6p of 140 kg. 8 m 200 kg. 9 m 280 kg. 9 m ] , 0.56 cmt for 11 m, 0.60 cmt for 13 m, 0.67 cmt for 15 m per pole including muffing with pole pit digging by hydra m / c. 86 clamp suitablefor 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long h beam ( each weight 3.2 kg ) 87 11kv outgoing lines ( 06 nos bays ) supply, of 200 kg., 9.0 mtrs. long pcc poles 88 supply, of d.c. channel 4.8 mtr centre 100x50x6mm for 11kv ( each weight 99.90 kg ) 89 supply, of 11 kv top clamps angle type65x65x6 mm 90 supply, of mesh earthing for new 33 / 11kv sub station inblack cotton soil as per schedule g 3.1 91 supply of 1500 kvar auto switch, 11 kv capacitor bank complete with individual fuses , interconnection , mounting racks, external fuses, mounting arrangement, bas insulator and accessories with earthing and marshelling box 92 supply, of earthing of capacitor bank as per schedule g 6.1 ( for black cotton soil ) 93 supply and laying of 32mm x 6mm copper strip fromearth electrode directly in the ground as requiredcomplete in all respect. 94 miscellaneousitems ( i ) safety helmets 95 ( ii ) tong tester digital ( 1000a, 500v ) with associates accessory 96 ( iii ) chain pully block 3ton with 15 metre chain. 97 ( iv ) wall mounting type holder for hydrometer 98 megger anolog 1000 v 99 megger anolog5000 v. 100 ( vii ) battery hydrometer 101 ( viii ) rubber hand gloves for 15kv ( seamless ) 102 ( ix ) transformer oil dielectric breakdown test kit 103 supplyof fire bucket, round bottom made of g.i. sheet 9 11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of engineer in charge. 104 supplyof shock treatment chart ( prescribed under i.e. rules ) duly framed with glass and supported from back with hard board or soft board with supply of all material labour t&p for proper completion of work 105 supplyof fire extinguisher, abc type 9.00 kg. capacity ( isi marked is : 15683 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 106 supplyof c02 type fire extinguisher 6.5 kg. capacity ( isi marked is : 2878 & tac approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 107 supply of 11kv 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. 108 earth resistance tester ( 20 / 200 / 2000ohms ) digital 109 filter machine 250gph ( transformer oil filtration purpose ) 110 supplyfollowing capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch tso 100 series with contactors, hrcfuses, isolating switch metering instrument & instrument box with cts etc. in case of tpn, complete in all respect.auto / mannual selector switch24hour programmable timer. 40a tpn 111 mccb ) suitable for 3 phase & n, 4 pole, ac supply with micro processor release ( mccb, 25ka, 40 & 100 amps, 4p ) 112 steel enclosure, neutral bar suitable for mcb / rcbos / mccb ( 63a / 100a, 3p / 4p enclosure ) 113 supply of 4 x 10sq.mm aluminium cable a2xfy type. 114 supply & fixing of 7 mtr gi octagonal pole of approved make ( top dia 70mm, bottom dia 130mm and base plate 12mm thik ) having 3mm thikness with single arm bracket ( 1 mtr length ) on rcc foundation including the cost of foundation, foundation bolts, excavation & backfilling and required t&p completee in all respect 115 supplyof led street light fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 watt. confirming to ip 66 protection complete in all respects cat aaa...